background image

 

 

79

 

Modbus Fault Decoding for Monitors 

The following table provides the fault code data for all G7 faults for Modbus fault trace / fault history registers. 

 

 

Table 4.17 Modus Fault Decoding Information 

For Monitors U2-01, U2-02, U3-01 thru U3-04, and U3-09 thru U3-14 

Data 

Decimal 

Fault 

Data 

Decimal 

Fault 

0001h 

PUF - DC Bus Fuse Open  

0021h 

33 

CE - Modbus Communication Loss 

0002h 

UV1 - DC Bus Undervoltage 

0022h 

34 

BUS - Option Communication Error 

0003h 

UV2 - CTL PS Undervoltage 

0023h 

35 

E-15 - SI-F/G Communication Error 

0004h 

UV3 - MC Answerback 

0024h 

36 

E-10 - SI-F/G Communication Loss 

0005h 

SC - Short Circuit 

0025h 

37 

CF - Loss of Motor Control 

0006h 

GF - Ground Fault 

0026h 

38 

SVE - Zero Servo Fault 

0007h 

OC - Over Current 

0027h 

39 

EF0 - Option External Fault 

0008h 

OV - DC Bus Overvoltage 

0028h 

40 

FBL - PID Feedback Loss 

0009h 

OH - Heatsink Overtemperature 

0029h 

41 

UL3 - Undertorque Detection 1 

000Ah 

10 

OH1 - Heatsink MAX Temperature 

002Ah 

42 

UL4 - Undertorque Detection 2 

000Bh 

11 

OL1 - Motor Overload 

002Bh 

43 

OL7 - High Slip Braking Overload 

000Ch 

12 

OL2 - Inverter Overload 

002Ch 

44 

EF9 - External Fault S9 

000Dh 

13 

OL3 - Overtorque Detection 1 

002Dh 

45 

EF10 - External Fault S10 

000Eh 

14 

OL4 - Overtorque Detection 2 

002Eh 

46 

EF11 - External Fault S11 

000Fh 

15 

RR - Braking Transistor Failure 

002Fh 

47 

EF12 - External Fault S12 

0010h 

16 

RH - Braking Resistor Overheat 

0030h 

48 

Reserved 

0011h 

17 

EF3 - External Fault S3 

0031h 

49 

VCN - Neutral Point Detection 

0012h 

18 

EF4 - External Fault S4 

0032h 

50 

Reserved 

0013h 

19 

EF5 - External Fault S5 

0033h 

51 

Reserved 

0014h 

20 

EF6 - External Fault S6 

0034h 

52 

Reserved 

0015h 

21 

EF7 - External Fault S7 

0035h 

53 

Reserved 

0016h 

22 

EF8 - External Fault S8 

0036h 

54 

Reserved 

0017h 23 

Reserved 

0037h  55 

Reserved 

0018h 

24 

OS - Overspeed 

0038h 

56 

PGOH - Encoder (PG) Loss 

0019h 

25 

DEV - Speed Deviation 

0039h 

57 

E-5 - SI-T Communication Loss 

001Ah 

26 

PGO - Encoder (PG) Loss 

003Ah 

58 

CF2 - Loss of Motor Control 2 

001Bh 

27 

PF - Input Phase Loss 

003Bh 

59 

SER - Speed Search Error 

001Ch 

28 

LF - Output Phase Loss 

003Ch 

60 

CFAL1 - CASE Fault 1* 

001Dh 

29 

OH3 - Motor Overheat 1 

003Dh 

61 

CFAL2 - CASE Fault 2* 

001Eh 

30 

OPR - Operator Disconnected 

003Eh 

62 

CFAL3 - CASE Fault 3* 

001Fh 

31 

ERR - EEPROM Read/Write Error 

003Fh 

63 

CFAL4 - CASE Fault 4* 

0020h 

32 

OH4 - Motor Overheat 2 

0040h 

64 

CFAL5 - CASE Fault 5* 

*  For drives with custom (CASE) software, the fault text could be different. 

 

Содержание Varispeed G7

Страница 1: ...Modbus Communication Manual G7 Drive Drive Model CIMR G7U Document Number TM G7 11...

Страница 2: ...2 Page intentionally blank...

Страница 3: ...capacitor remains charged even after the power supply is turned off Status indicator LEDs and Digital Operator display will be extinguished when the DC bus voltage is below 50 VDC To prevent electric...

Страница 4: ...pertains to the G7 drive In this document the word inverter ac drive and drive may be used interchangeably For details on installation and operation of the G7 drive refer to the G7 Drive Technical Ma...

Страница 5: ...isters Function Code 10H 27 No Response 29 Error Codes 29 CRC 16 Calculations 30 Chapter 3 Troubleshooting 31 General Information 33 RS 232 Communication 35 RS 422 RS 485 Communication 37 RS 422 RS 48...

Страница 6: ...6 Notes...

Страница 7: ...connect the G7 drive to a RS 232 RS 422 or RS 485 network Connection Check Sheet 8 Verify Operation 9 G7 Drive Connections 10 Serial Network Connections 11 Communications Parameters 13 Run Stop and F...

Страница 8: ...fer to Figure 1 1 G7 Diagram for the location of drive connectors Use a DB9 to RJ 45 adapter with a standard Ethernet CAT 5 patch cable or use Yaskawa cable UWR00468 2 Do NOT connect this cable to an...

Страница 9: ...cal Manual for information on connecting and operating the G7 drive Remove power from the G7 drive and wait for the charge lamp to be completely extinguished Wait at least five additional minutes for...

Страница 10: ...10 G7 Drive Connections Figure 1 2 G7 Drive Connections...

Страница 11: ...t is recommended that Yaskawa cable UWR00468 2 be used Note It is not possible to use the drive s keypad and an RS 232 connection at the same time Figure 1 3 RS 232 Network Connection RS 422 RS 485 4...

Страница 12: ...imum of 31 devices may reside on any network segment before a repeater is required The maximum segment length is 4000 ft 1200 m Set the Termination Resistor S1 switch to ON slide the switch to the rig...

Страница 13: ...Value Description Baud rate 9600 Parity None Stop Bits 1 Node Address N A RS 422 RS 485 Communication Node Address H5 01 The node address is set through G7 drive parameter H5 01 When communicating via...

Страница 14: ...cording to H5 04 if communication is lost a message is not received for more than 2 seconds after successful communication has been initiated Table 1 5 Communication Fault Detection Selection Paramete...

Страница 15: ...top command may be set to Terminals B1 01 1 while the Frequency Reference command may be set to Serial Communication B1 02 2 Run Stop Source Table 1 7 Run Stop Method Selection B1 01 Operation Method...

Страница 16: ...H5 03 H5 07 Baud Rate Parity Data Bits Stop Bits 1 1 5 Verify that the communication parameters match 2 RS 422 RS 485 Communication 2 1 Verify that the G7 drive is connected correctly 2 2 Verify that...

Страница 17: ...command message to the G7 drive from the controller and verify the data of the command and response messages 3 1 Verify the contents of the command message 3 2 Verify the contents of the response mes...

Страница 18: ...18 Notes...

Страница 19: ...age telegram contents and configuration Protocol 20 Read Multiple Registers Function Code 03H 21 Write Single Register Function Code 06H 23 Loop Back Test Function Code 08H 25 Write Multiple Registers...

Страница 20: ...sage from the slave The following sections review the format of the command and response messages for each function Message Functions Supported The following table lists the Modbus function codes avai...

Страница 21: ...ster address is 20h 0020h The quantity indicates how many consecutive registers are to be read The quantity may range from 1 to 8 registers If an invalid quantity is entered error code 03h is returned...

Страница 22: ...section of the response message contains the data for the registers requested read in this case registers 20h 21h 22h and 23h Their data is 20h 1770h 21h 1770h 22h 0109h and 23h 0h Read Multiple Regis...

Страница 23: ...sage there is no response message The function code of this message is 06h write single register In the command message above the register address is 01h 0001h The data section contains the data to be...

Страница 24: ...er Fault Response Message Description Data Slave Address 01h Function Code 86h Error Code 21h Upper 82h CRC 16 Lower 78h The fault response message contains the same slave address as the command messa...

Страница 25: ...at 01h Broadcast address 0 is not valid for Loop Back test commands The function code of this message is 08h Loop Back test The test code must be set to 0000h This function specifies that the data pa...

Страница 26: ...01h Function Code 88h Error Code 01h Upper 87h CRC 16 Lower C0h The fault response message contains the same slave address as the command message indicating to the master which slave is responding The...

Страница 27: ...to be written The quantity may range from 1 to 16 registers If an invalid quantity is entered error code of 03h is returned in a fault response message In this command message there are two consecuti...

Страница 28: ...case the quantity is 2 Write Multiple Registers Fault Response Message Table 2 13 Write Registers Fault Response Message Description Data Slave Address 01h Function Code 90h Error Code 02h Upper CDh C...

Страница 29: ...et in the slave 4 When it takes longer than 2 seconds to send a message 5 When the time interval between characters exceeds 3 5 ms 6 When the command message data length is not proper Error Codes Tabl...

Страница 30: ...in the transmitted CRC 16 field If the two values are not equal the entire message is invalid Detailed examples of a CRC 16 generation using Quick Basic and C are shown below CRC 16 Calculation Examp...

Страница 31: ...ables for i 0 i bufLen i Loop through characters of input array crc_0 unsigned long buf i 0x00ff XOR current character with 0x00ff for j 0 j 8 j Loop through characters bits crc_1 crc_0 1 0x7fff shift...

Страница 32: ...32 Notes...

Страница 33: ...pter 3 Troubleshooting This chapter describes basic troubleshooting methods for serial communication General Information 34 RS 232 Communication 35 RS 422 RS 485 Communication 37 RS 422 RS 485 Self Te...

Страница 34: ...tomer support is necessary please have the information below available 1 G7 Drive Model CIMR _____ 4 Control Board ETC _____ 2 Input__ VAC____Hz 5 Software ID U1 14 __________________ 3 Serial Number_...

Страница 35: ...s communication parameters H5 02 H5 03 H5 07 Baud Rate Parity Data Bits Stop Bits 1 1 5 Verify that the communication parameters match 2 Check the controller RS 232 wiring requirements 2 1 CTS Clear...

Страница 36: ...r RXD and GND 4 1 1 Verify that the message pulse train exists and contains the correct number of pulses Refer to the chapter Message Formats for information on the message contents 4 1 2 Verify that...

Страница 37: ...ecord the G7 drive communication parameters H5 01 H5 02 H5 03 H5 07 Baud Rate Parity Data Bits Stop Bits 1 1 6 Verify that the communication parameters match 1 7 For RS 485 2 wire networks only verify...

Страница 38: ...at the signal levels adhere to the RS 422 RS 485 standard 4 2 Insert a data analyzer in the RS 422 RS 485 circuit and capture the message sent by the controller in a hexadecimal format Record the comm...

Страница 39: ...ge Formats for information on the message contents 5 1 2 Verify that the signal levels adhere to the RS 422 RS 485 standard 5 2 Capture the response message in hexadecimal format and record it below 5...

Страница 40: ...to be completely discharged Measure the DC bus voltage and verify that it is at a safe level Connect jumper wires to the following G7 drive control terminals see picture below Connect S to R Connect S...

Страница 41: ...3 Monitor Registers Read Only 44 Parameter Registers Read Write 52 A Parameters 53 B Parameters 54 C Parameters 56 D Parameters 57 E Parameters 58 F Parameters 59 H Parameters 63 L Parameters 68 N Par...

Страница 42: ...Function set by setting of H1 03 9h Multi Function Digital Input Terminal S6 Function set by setting of H1 04 Ah Multi Function Digital Input Terminal S7 Function set by setting of H1 05 Bh Multi Fun...

Страница 43: ...ti Function Digital Input Terminal S4 Function set by setting of H1 02 7h Reserved 8h Reserved 9h Reserved Ah Reserved Bh Reserved Ch Multi Function Digital Input Terminal S5 Function set by setting o...

Страница 44: ...eserved 2h Reserved 3h Fault Reset Signal 4h Speed Agree 5h Inverter Ready 6h Minor Fault Alarm 7h Major Fault 8h Reserved 9h Reserved Ah Reserved Bh Reserved Ch Reserved Dh Reserved Eh Frequency Refe...

Страница 45: ...verheat 0h EF3 External Fault 3 1h EF4 External Fault 4 2h EF5 External Fault 5 3h EF6 External Fault 6 4h EF7 External Fault 7 5h EF8 External Fault 8 6h Reserved 7h OS Overspeed 8h DEV Speed Deviati...

Страница 46: ...t 7 Dh Reserved Eh Reserved 0019h Minor Fault Contents 1 Fh OS Overspeed 0h DEV Speed Deviation 1h PGO Encoder PG Feedback Loss 2h OPR Operator Disconnected 3h CE Communication Loss 4h BUS Communicati...

Страница 47: ...raking Resistor Fault 5h PUF DC Bus Fuse Failure 6h FBL PID Feedback Loss 7h EFx or EFO External Fault 8h CPF Control Board Hardware Fault 9h OL1 or OL3 or OL4 Motor Overload Overtorque 1 or 2 Ah PGO...

Страница 48: ...ital Output 2 M3 M4 2h Multi Function Digital Output 3 M5 M6 3h Multi Function Digital Output 4 P3 C3 4h Multi Function Digital Output 5 P4 C4 002Dh Digital Output Status 5h Fh Reserved U1 07 0031h Ma...

Страница 49: ...unction Digital Output 2 M3 M4 2h Multi function Digital Output 3 M5 M6 3h Multi function Digital Output 4 P3 C3 4h Multi function Digital Output 5 P4 C4 5h Reserved 6h Reserved 7h Fault Output 8h Res...

Страница 50: ...h Estimated Motor Flux Units 0 1 U1 43 006Ah Motor Flux Compensation Units 0 1 U1 44 006Bh ASR Output Without Filtering Units 0 01 U1 45 006Ch Feed Forward Control Output Units 0 01 U1 48 006Fh Stabil...

Страница 51: ...e 4 17 U3 04 0803h 4th Most Recent Fault See Table 4 17 U3 05 080Ah Elapsed Time at Most Recent Fault Units 1 0hr U3 06 080Bh Elapsed Time at 2nd Most Recent Fault Units 1 0hr U3 07 080Ch Elapsed Time...

Страница 52: ...writable during Run Blank the parameter is Read Only during Run The Access columns describe the accessibility and access level for a given control mode see A1 01 for access levels and A1 02 for contr...

Страница 53: ...er 8 0h 6ffh 0 01 0h A A A A A A2 09 010Eh User Parameter 9 0h 6ffh 0 01 0h A A A A A A2 10 010Fh User Parameter 10 0h 6ffh 0 01 0h A A A A A A2 11 0110h User Parameter 11 0h 6ffh 0 01 0h A A A A A A2...

Страница 54: ...0 10 0 Hz 0 1 Hz 0 5 Hz A A A A A b2 02 018Ah DC Injection Current 0 100 1 50 A A A b2 03 018Bh DC Injection Time at Start 0 0 10 0 Sec 0 01 Sec 0 0 Sec A A A A A b2 04 018Ch DC Injection Time at Stop...

Страница 55: ...isabled 1 Alarm b5 12 01B0h PID Feedback Loss Detection Selection 2 Fault 1 0 A A A A A b5 13 01B1h PID Feedback Loss Detection Level 0 100 1 0 A A A A A b5 14 01B2h PID Feedback Loss Detection Time 0...

Страница 56: ...Slip Compensation Limit 0 250 1 200 A A 0 Disabled C3 04 0212h Slip Compensation During Regeneration 1 Enabled 1 0 A A 0 Disabled C3 05 0213h Output Voltage Limit Selection 1 Enabled 1 0 A A A C4 01...

Страница 57: ...0 0 Hz 0 01 Hz 0 0 Hz R A A A A A d1 17 0292h Jog Frequency Reference 0 0 400 0 Hz 0 01 Hz 6 0 Hz R Q Q Q Q Q d2 01 0289h Frequency Reference Upper Limit 0 0 110 0 0 1 100 0 A A A A A d2 02 028Ah Freq...

Страница 58: ...0317h Motor Iron Loss 0 65535 W 1 W kVA Dep A A E2 11 0318h Motor Rated Power 0 00 650 00 kW 0 01 kW kVA Dep Q Q Q Q Q E2 12 0328h Saturation Compensation 3 1 30 5 00 0 01 1 30 A A A 0 V F 1 V F w PG...

Страница 59: ...c 0 1 Sec 1 0 Sec A A A F1 10 0389h PG Deviation Level 0 50 1 10 A A A F1 11 038Ah PG Deviation Time 0 0 10 0 Sec 0 1 Sec 0 5 Sec A A A F1 12 038Bh PG Gear Teeth 1 0 1000 1 0 A F1 13 038Ch PG Gear Tee...

Страница 60: ...PID Output 38 PID Setpoint 42 Estimated Motor Flux 43 Id Compensation Value 44 ASR Output Without Filter 45 Feed Forward Output F4 01 0391h AO 08 AO 12 Option Kit Channel 1 Function Selection 48 Stab...

Страница 61: ...larm 37 During Run 2 F5 01 0399h DO 02C DO 08 Option Kit Channel 1 Selection 38 drive Enable 1 0h F5 02 039Ah DO 02C DO 08 Channel 2 Selection See F5 01 1 01h A A A A A F5 03 039Bh DO 08 Channel 3 Sel...

Страница 62: ...1 0 A A A A A 0 Display in Amps F6 05 03A6h Output Current Unit Selection 1 100 8192 1 0 A A A A A 0 Disabled F6 06 03A7h Torque Reference Limit From Option Card Selection 1 Enabled 1 0 A A 0 Ramp to...

Страница 63: ...ult Reset 15h Fast Stop N O 16h Motor 2 Selection 17h Fast Stop N C 18h Timer Function Input 19h PID Disable 1Ah Multi Step Accel Decel 2 1Bh Program Lockout 1Ch Trim Control Increase 1Dh Trim Control...

Страница 64: ...S7 Selection See H1 01 1 06h A A A A A H1 06 0405h Terminal S8 Selection See H1 01 1 08h A A A A A H1 07 0406h Terminal S9 Selection See H1 01 1 05h A A A A A H1 08 0407h Terminal S10 Selection See H...

Страница 65: ...on Selection 38h drive Enable 1 0h H2 02 040Ch Terminal M3 M4 Selection See H2 01 1 1h A A A A A H2 03 040Dh Terminal M5 M6 Selection See H2 01 1 2h A A A A A H2 04 040Eh Terminal P3 C3 Selection See...

Страница 66: ...erminal A3 Gain 0 0 1000 0 0 1 100 0 R A A A A A H3 07 0416h Terminal A3 Bias 100 0 100 0 0 1 0 0 R A A A A A 0 0 10 VDC 1 10 10 VDC H3 08 0417h Analog Input Terminal A2 Signal Type Selection Set Swit...

Страница 67: ...00 bps H5 02 0426h Baud Rate 4 19200 bps 1 3 A A A A A 0 No Parity 1 Even Parity H5 03 0427h Parity Selection 2 Odd Parity 1 0 A A A A A 0 Ramp to Stop 1 Coast to Stop 2 Fast Stop C1 09 H5 04 0428h Co...

Страница 68: ...A A A A L2 07 048Bh Powerloss Ride Thru Accel Time 0 0 25 5 Sec 0 1 Sec 0 0 Sec A A A A A L2 08 048Ch KEB Frequency Gain 0 300 1 100 A A A A A 0 Disabled 1 General Purpose L3 01 048Fh Stall Preventio...

Страница 69: ...Torque Detection 2 Selection OL4 UL4 8 Undertorque Run Fault 1 0 A A A A A L6 05 04A5h Torque Detection 2 Level 0 300 1 150 A A A A A L6 06 04A6h Torque Detection 2 Time 0 0 10 0 Sec 0 1 Sec 0 1 Sec A...

Страница 70: ...6h Cooling Fan On Off Selection 1 Fan Always On 1 0 A A A A A L8 11 04B7h Fan Off Delay Time After Stop Command 0 300 Sec 1 Sec 60 Sec A A A A A L8 12 04B8h Ambient Temperature 45 60 Deg 1 Deg 45 Deg...

Страница 71: ...0 0 0 1 15 A n4 11 059Eh High Low Speed Observer Changeover Frequency 40 70 Hz 1 Hz 70 Hz A n4 15 05A2h Low Speed Regenerative Coefficient 1 0 0 3 0 0 1 0 3 A n4 17 05A4h Torque Adjustment Gain at Low...

Страница 72: ...U ID 29 Accumulated kWh 30 Accumulated MWh 32 ACR Iq Output 33 ACR Id Output 34 OPE Detected 36 PID Input 37 PID Output 38 PID Setpoint 39 Transmit Error 40 FAN Elapsed Time 42 Estimated Motor Flux 43...

Страница 73: ...6 050Ah Operator Disconnect Detection Selection 1 Enabled 1 0 A A A A A o2 07 050Bh Accumulated Time Initial Setting 0 65535 H 1 H 0 H A A A A A 0 Power On Time o2 08 050Ch Accumulated Time Selection...

Страница 74: ...arameter 13 P2 04 060Dh CASE Parameter 14 P2 05 060Eh CASE Parameter 15 P2 06 060Fh CASE Parameter 16 P2 07 0610h CASE Parameter 17 P2 08 0611h CASE Parameter 18 P2 09 0612h CASE Parameter 19 P2 10 06...

Страница 75: ...Bit Description 0h Forward Run Input 1h Reverse Run Input 2h Multi Function Digital Input Terminal S3 Function set by setting of H1 01 3h Multi Function Digital Input Terminal S4 Function set by sett...

Страница 76: ...on Output 2 M3 M4 Dh Multi Function Output 3 M5 M6 Eh Motor 2 Selected 2000h Status Fh Zero Servo Complete 2001h Speed Feedback Monitor Keypad Monitor U1 05 2002h Torque Reference Monitor Keypad Monit...

Страница 77: ...GO Encoder PG Feedback Loss Ah PF Input Phase Loss Bh LF Output Phase Loss Ch OH3 Motor Overheat 1 Dh OPR Operator Disconnected Eh ERR EEPROM Write Failure 200Ah Error 2 Fh OH4 Motor Overheat 2 0h CE...

Страница 78: ...ta in the off line memory area but if power is lost all of the changes will be lost The ACCEPT command can be performed as many times as needed An ACCEPT command is performed by writing a value of zer...

Страница 79: ...h 44 EF9 External Fault S9 000Dh 13 OL3 Overtorque Detection 1 002Dh 45 EF10 External Fault S10 000Eh 14 OL4 Overtorque Detection 2 002Eh 46 EF11 External Fault S11 000Fh 15 RR Braking Transistor Fail...

Страница 80: ...80 Notes...

Страница 81: ...81 Chapter 5 User Notes This chapter allows the user to enter information specific to their application Notes 82 User Parameter Settings 83 Hex Dec Conversion Table 91...

Страница 82: ...82 Notes drive drive Name Date...

Страница 83: ...er 20 0h A2 21 User Parameter 21 0h A2 22 User Parameter 22 0h A2 23 User Parameter 23 0h A2 24 User Parameter 24 0h A2 25 User Parameter 25 0h A2 26 User Parameter 26 0h A2 27 User Parameter 27 0h A2...

Страница 84: ...on 0 b5 19 PID Setpoint 0 00 b6 01 Dwell Reference at Start 0 0 Hz b6 02 Dwell Time at Start 0 0 Sec b6 03 Dwell Reference at Stop 0 0 Hz b6 04 Dwell Time at Stop 0 0 Sec b7 01 Droop Level 0 00 b7 02...

Страница 85: ...cy Reference 5 0 0 Hz d1 06 Frequency Reference 6 0 0 Hz d1 07 Frequency Reference 7 0 0 Hz d1 08 Frequency Reference 8 0 0 Hz d1 09 Frequency Reference 9 0 0 Hz d1 10 Frequency Reference 10 0 0 Hz d1...

Страница 86: ...Motor 2 60 0 Hz E3 05 Midpoint Frequency Motor 2 Control Meth E3 06 Midpoint Voltage Motor 2 Control Meth E3 07 Minimum Frequency Motor 2 Control Meth E3 08 Minimum Voltage Motor 2 Control Meth E4 01...

Страница 87: ...on 0 F6 03 EF0 Fault Selection 1 F6 04 CP 916 Trace Sample Time 0 F6 05 Output Current Unit Selection 0 F6 06 Torque Reference Limit Select 0 F6 08 SI T Communication Loss Select 1 F6 09 SI T Loss Ret...

Страница 88: ...20 Sec L2 01 Power Loss Ride Thru Selection 0 L2 02 Power Loss Ride Thru Time 0 1 Sec L2 03 Minimum Baseblock Time 0 5 Sec L2 04 Voltage Recovery Ramp Time 0 3 Sec L2 05 Undervoltage Detection Level...

Страница 89: ...4 08 Speed Estimator P Gain 15 n4 10 Observer Gain at High Speed 15 n4 11 Observer Switch Frequency 70 Hz n4 15 Low Speed Regen Coefficient 1 0 3 n4 17 Torque Adjustment Gain 1 1 n4 18 Motor Cable Res...

Страница 90: ...P1 09 CASE Parameter 9 0 P1 10 CASE Parameter 10 0 P2 01 CASE Parameter 11 0 P2 02 CASE Parameter 12 0 P2 03 CASE Parameter 13 0 P2 04 CASE Parameter 14 0 P2 05 CASE Parameter 15 0 P2 06 CASE Paramete...

Страница 91: ...125 B1 177 E5 229 16 22 4A 74 7E 126 B2 178 E6 230 17 23 4B 75 7F 127 B3 179 G7 231 18 24 4C 76 80 128 B4 180 E8 232 19 25 4D 77 81 129 B5 181 E9 233 1A 26 4E 78 82 130 B6 182 EA 234 1B 27 4F 79 83 13...

Страница 92: ...AMERICA INC Marketing Communications 16555 West Ryerson Road New Berlin WI 53151 U S A Phone 1 800 YASKAWA 800 927 5292 Fax 262 782 3418 Internet http www yaskawa com YASKAWA ELECTRIC CORPORATION New...

Отзывы: