5
-48
* If the multi-function input is set to 79 and the input value is “closed,” operation will be performed with a speed specification of 0.
16
Motor switch command (Motor 2 selection)
Yes
Yes
Yes
Yes
Yes
-
17
Emergency stop (Normally closed condition: Deceleration to stop in deceleration
time set in C1-09 when OFF)
Yes
Yes
Yes
Yes
Yes
6-15
18
Timer function input (Functions are set in b4-01 and b4-02 and the timer function
outputs are set in H1-
and H2-
.)
Yes
Yes
Yes
Yes
Yes
6-101
19
PID control disable (ON: PID control disabled)
Yes
Yes
Yes
Yes
Yes
6-105
1A
Accel/Decel time 2
Yes
Yes
Yes
Yes
Yes
6-17
1B
Constants write enable (ON: All constants can be written-in. OFF: All constants
other than frequency monitor are write protected.)
Yes
Yes
Yes
Yes
Yes
6-150
7-19
1C
Trim control increase (ON: d4-02 frequency is added to analog frequency refer-
ence.)
Yes
Yes
Yes
Yes
Yes
6-79
1D
Trim control decrease (ON: d4-02 frequency is subtracted from analog frequency
reference.)
Yes
Yes
Yes
Yes
Yes
6-79
1E
Analog frequency reference sample/hold
Yes
Yes
Yes
Yes
Yes
6-80
20 to
2F
External fault (Desired settings possible)
Input mode: NO contact/NC contact, Detection mode: Normal/during operation
Yes
Yes
Yes
Yes
Yes
6-82
30
PID control integral reset (reset when reset command is input or when stopped
during PID control)
Yes
Yes
Yes
Yes
Yes
6-105
31
PID control integral hold (ON: Hold)
Yes
Yes
Yes
Yes
Yes
6-105
32
Multi-step speed reference 4
Yes
Yes
Yes
Yes
Yes
-
34
PID soft starter
Yes
Yes
Yes
Yes
Yes
6-105
35
PID input characteristics switch
Yes
Yes
Yes
Yes
Yes
6-105
60
DC injection braking command (ON: Performs DC injection braking)
Yes
Yes
Yes
Yes
Yes
6-14
61
External search command 1 (ON: Speed search from maximum output frequency) Yes
No
Yes
No
Yes
6-64
62
External search command 2 (ON: Speed search from set frequency)
Yes
No
Yes
No
Yes
6-64
63
Field weakening command (ON: Field weakening control set for d6-01 and d6-
02)
Yes
Yes
No
No
No
-
64
External speed search command 3
Yes
Yes
Yes
Yes
Yes
-
65
KEB (deceleration at momentary power loss) command (NO contact)
Yes
Yes
Yes
Yes
Yes
-
66
KEB (deceleration at momentary power loss) command (NO contact)
Yes
Yes
Yes
Yes
Yes
-
67
Communications test mode (“Pass” is displayed when the communications test is
passed.)
Yes
Yes
Yes
Yes
Yes
6-100
68
High-slip braking (HSB)
Yes
Yes
No
No
No
-
71
Speed/torque control change (ON: Torque control)
No
No
No
Yes
Yes
6-125
6-130
72
Zero-servo command (ON: Zero-servo)
No
No
No
Yes
No
6-141
77
Speed control (ASR) proportional gain switch (ON: C5-03)
No
No
No
Yes
Yes
6-132
78
Polarity reversing command for external torque reference
No
No
No
Yes
Yes
6-125
79
Brake ON signal (Brake Signal)
No
No
No
No
Yes
-
Set-
ting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2