6
-42
Fig 6.32
•
With vector control, the carrier frequency is fixed to the Carrier Frequency Upper Limit in C6-03 if user-
set or by the carrier frequency set in C6-02.
•
To fix the carrier frequency, set C6-03 and C6-04 to the same value, or set C6-05 to 0.
•
If the settings are as shown below, OPE11 (Constant setting error) will occur.
If Carrier Frequency Proportional Gain (C6-05) > 6 and C6-03 < C6-04.
•
The Inverter overload current level can be reduced by the carrier frequency setting, and an OL2 (Inverter
overload) may be detected even if the overload current is smaller than 150%. The reduction levels of the
Inverter overload current are shown in the following figures.
Fig 6.33 Reduction Levels for V/f, V/f with PG, Open-loop Vector 1, and Flux Vector Control
C6-03
C6-04
Output frequency
Output frequency
×
C6-05
×
K*
E1-04
Max. Output Frequency
Carrier Frequency
K is the coefficient determined by the set
value in C6-03.
C6-03
≥
10.0 kHz: K=3
10.0 kHz > C6-03
≥
5.0 kHz: K=2
5.0 kHz < C6-03: K=1
*
100%
15 kHz
0
Overload current reduction level
Carrier frequency
50%
80%
200 V Class,
22 kW
10 kHz