YASKAWA
SIEP C730600 88F MECHATROLINK-III Technical Manual
39
Bit
Name
Description
20
Multi-function input terminal 7
Multi-function input terminal S7
0: Multi-function input terminal S7 is OFF
1: Multi-function input terminal S7 is ON
21
Multi-function input terminal 8
Multi-function input terminal S8
0: Multi-function input terminal S8 is OFF
1: Multi-function input terminal S8 is ON
*1
GA500 does not have multi-function digital input 8.
■
INVCMD_IO Command
Vendor Specific
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Not used
Vendor Specific
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
Not used
Vendor Specific
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Not used
bit31
bit30
bit29
bit28
Vendor Specific
bit27
bit26
bit25
bit24
Reserved (0)
Not used
Table 9.7 SEL_REF Reference Data Codes
Selection Code (Hex.)
Monitor Name
Contents
0
Nothing Selected
-
1
Torque Compensation
Unit: 0.1%
2
Analog output terminal 1 output
Enabled when
H4-01 = 000
3
1000-Series Drives, GA700, GA800, CR700, and CH700: Analog
Output Terminal 2 Output
GA500: Not used
1000-Series Drives, GA700, GA800, CR700, and CH700: Enabled
when
H4-04 = 000
GA500: -
4
Drive terminal output
-
5
PID Setpoint
Unit: 0.01%
6
Pulse Output
Unit: 1 Hz
7
V/f gain
-
8
Not used
-
9
Command selection setting
Bit 1: PID setpoint enabled
Table 9.8 SEL_MON Monitor Data Codes
Selection Code (Hex.)
Monitor Name
Contents
0
Nothing Selected
-
1
Motor Speed
Displayed in
U1-05
and determined by
o1-03
.
2
Torque Reference (Monitor)
Displayed in
U1-09
(0.1%).
3
1000-Series Drives, GA700, GA800, CR700, and CH700: Speed
Detection PG1 Counter
GA500: Not used
-
4
Frequency Reference
Displayed in
U1-01
and determined by
o1-03
.
5
Analog input Terminal A2
Displayed in
U1-14
(0.1%).
6
DC Bus Voltage
Displayed in
U1-07
(1 V).
7
Inverter Alarm
-
8
Inverter Warning
-