![YASKAWA SI-ET3 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/yaskawa/si-et3/si-et3_technical-manual_3272479035.webp)
YASKAWA
SIEP C730600 88F MECHATROLINK-III Technical Manual
35
ALM_CLR Response
Byte
Response
Description
0
ALM_CLR (06 (Hex.))
Command code
1
RWDT
Watchdog data
2
CMD_STAT
Refer to page
3
4
ALM_CLR_MOD
The value set in the command.
5
6
Reserved (0)
Not used
7
・
・
31
◆
SYNC_SET: 0D (Hex.) (Start Synchronous Communication Command)
The SYNC_SET command starts synchronous communications. The SYNC_SET command starts synchronous
communications. This command also restores synchronous if communications become asynchronous due to any
fault. The command can be used in communication phases 2 and 3. Completing this command commences
watchdog data error detection.
SYNC_SET Command
Byte
Command
Description
0
SYNC_SET (0D (Hex.))
Command code
1
WDT
Watchdog data
2
CMD_CTRL
Refer to page
3
4
Reserved (0)
Not used
5
6
7
・
・
31
SYNC_SET Response
Byte
Response
Description
0
SYNC_SET (0D (Hex.))
Command code
1
RWDT
Watchdog data
2
CMD_STAT
Refer to page
3
4
Reserved (0)
Not used
5
6
7
・
・
31