![YASKAWA SGDV-120A Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/yaskawa/sgdv-120a/sgdv-120a_manual_907681035.webp)
We need Pn002.2 set to 0 (Factory setting). This will enable the SEN input to be used to send the encoder
position to the motion controller.
Setting up the absolute encoder is necessary in the following cases:
When starting the machine for the first time
When an encoder backup error alarm (A.810) is generated
When an encoder checksum error alarm (A.820) is generated
When initializing the rotational serial data of the absolute encoder
1. Precautions on Setup
Set up the encoder when the servo ON signal (/S-ON) is OFF.
Software and Parameters Setup
Yaskawa Servo Drive
Servo Drive Parameters:
Servo Drive Absolute Encoder Setup
The rotational data will be a value between -2 and +2 rotations when the absolute encoder setup is
executed. The reference position of the machine system will change. Set the reference position of the
host
controller to the position after setup.
If the machine is started without adjusting the position of the host controller, unexpected operation may
cause injury or damage to the machine. Take sufficient care when operating the machine.
Set up the absolute encoder with Fn008.
Содержание SGDV-120A
Страница 23: ...5 Read Position actual internal value 6 Set the negative of that value to home offset 7 Cycle power to drive ...
Страница 25: ...Factor and Offset Analog Monitor 1 Pn006 XX02 Load Meter ...
Страница 31: ...Install Standoff Install Buffer Board ...
Страница 32: ...Reinstall mounting screw Install jumper on servo adaptor J5 pin 2 3 next to the labeled SEN ...
Страница 33: ...Install wire from Buffer Board to all Yaskawa servo adaptors for SEN signal ...
Страница 34: ...Install Motor Encoder Cable with Battery ...