Start Up 4 - 6
9. Press the
S
key once to display E2-01 “Motor Rated FLA”.
This parameter is the foundation of motor protection. It can be entered when auto-tuning is performed. Set this
parameter according to the motor rated current (FLA). Press the
DATA/ENTER
key once. Use the
S
,
▼
, and
X
keys
to adjust E2-01 to the motor rated full load amps.
Ensure the
DATA/ENTER
key is pressed to enter the value in the Drive. “Entry Accepted” briefly appears and your
display is now flashing.
10. Press the ESC once. Press DATA/ENTER once. Press
S
key twice to display b1-02 “Run Source”. This parameter
selects where the Drive will receive the run command. Press the
DATA/ENTER
key once. Use the
S
or
▼
keys and
the
DATA/ENTER
key to set this parameter for the application.
Ensure the
DATA/ENTER
key is pressed to enter the selection in the Drive. “Entry Accepted” briefly appears and
the display is now not flashing.
11. Press the
▼
key once to display b1-01 “Reference Source”. This parameter selects where the Drive will receive the
speed command. Press the
DATA/ENTER
key once. Use the
S
or
▼
keys and the
DATA/ENTER
key to set this
parameter for the application.
Ensure the
DATA/ENTER
key is pressed to enter the selection in the Drive. “Entry Accepted” briefly appears and
the display is now not flashing.
12. Press the
S
key twice to display b1-03 “Stopping Method”.
This parameter selects the stopping method used when a stop command is given to the Drive.
Table 4.3 Motor Rated Current
Parameter
No.
Parameter Name
Digital Operator Display
Setting
Range
Factory
Setting
Menu
Location
E2-01
Motor Rated Current
Motor Rated FLA
kVA
Dependent
kVA
Dependent
Quick Setting
or
Programming
Table 4.4 Run Command Selection
Parameter
No.
Parameter Name
Digital Operator Display
Setting Choices
Setting
Range
Factory
Setting
Menu Location
b1-02
Run Command Selection
Run Source
0: Operator
1: Terminals
2: Serial Com
3: Option PCB
0 - 3
1
Quick Setting
or
Programming
Table 4.5 Speed Command Selection
Parameter
No.
Parameter Name
Digital Operator Display
Setting
Choices
Setting
Range
Factory
Setting
Menu Location
b1-01
Frequency Reference
Selection
Reference Source
0: Operator
1: Terminals
2: Serial Com
3: Option PCB
0 - 3
1
Quick Setting
or
Programming
Содержание P7
Страница 1: ...P7 Drive User Manual Model P7U Document Number TM P7 01...
Страница 58: ...Electrical Installation 2 30...
Страница 74: ...Digital Operator 3 16...
Страница 84: ...Start Up 4 10 Notes...
Страница 144: ...Programming 5 60 Notes...
Страница 210: ...Capacity Related Parameters B 6 Notes...
Страница 238: ...Spare Parts F 4 Notes...
Страница 239: ...EMC Compatibility G 1 Appendix G EMC Compatibility EMC Compatibility G 2 Electromagnetic Compatibility EMC G 3...
Страница 244: ...EMC Compatibility G 6 Notes...