Digital Operator 3 - 11
Quick Setting Menu (-QUICK-)
This menu is used to set/read the most commonly used parameters in the Drive. Follow the key operations below (Fig. 3.6) to
access the Quick Setting Menu:
Fig 3.6 Quick Setting Parameter Access Procedure
Use
and
keys to scroll through the “Quick Setting” parameter list.
Table 3.11 Quick Setting Parameter List
Parameter
Number
Parameter Name
Parameter
Number
Parameter Name
A1-00
Language Selection
b5-29
PI Square Root Gain
b1-01
Frequency Reference Selection
b5-30
Output Square Root Monitor Selection
b1-02
Run command Selection
b8-01
Energy Savings Control Selection
b1-03
Stopping Method Selection
C1-01
Acceleration Time 1
b1-04
Reverse Operation Selection
C1-02
Deceleration Time 1
b4-01
Delay-On Timer
b5-01
PI Mode Selection
d2-01
Frequency Reference Upper Limit
b5-02
Proportional Gain Setting
d2-02
Frequency Reference Lower Limit
b5-03
Integral Time Setting
E1-01
Input Voltage Setting
b5-04
Integral Limit Setting
E2-01
Motor Rated Current
b5-06
PI Output Limit
F6-01
Operation Selection After Communication Error
b5-07
PI Offset Adjustment
H3-02
Terminal A1 Gain Setting
b5-08
PI Primary Delay Time
H3-03
Terminal A1 Bias Setting
b5-09
PI Output Level Selection
H3-10
Terminal A2 Gain Setting
b5-10
PI Output Gain Setting
H3-11
Terminal A2 Bias Setting
b5-11
PI Output Reverse Selection
L2-01
Momentary Power Loss Detection Selection
b5-12
PI Feedback Reference Missing Detection Selection
L2-02
Momentary Power Loss Ride-thru Time
b5-13
PI Feedback Loss Detection Level
L4-05
Frequency Reference Loss Detection Selection
b5-14
PI Feedback Loss Detection Time
L4-06
Frequency Reference Level at Loss Frequency
b5-15
PI Sleep Function Start Level
L5-01
Number of Auto Restarts Attempts
b5-16
PI Sleep Delay Time
L5-03
Maximum Restart Time After Fault
b5-17
PI Accel/Decel Time
L6-01
Torque Detection Selection 1
b5-18
PI Setpoint Selection
L6-02
Torque Detection Level 1
b5-19
PI Setpoint Value
L6-03
Torque Detection Time 1
b5-20
PI Setpoint Display Setting
L8-11
Heatsink Cooling Fan Operation Delay Time
b5-21
PI Sleep Input Source
o1-01
User Monitor Selection
b5-22
PI Snooze Level
o1-05
LCD Brightness Adjustment
b5-23
PI Snooze Delay Time
o1-07
Second Line User Monitor Selection
b5-24
PI Snooze Deactivation Level
o1-08
Third Line User Monitor Selection
b5-25
PI Setpoint Boost Setting
o2-03
User Parameter Default Value
b5-26
PI Maximum Boost Time
o2-05
Frequency Operation Time Selection
b5-27
PI Snooze Feedback Level
o2-08
Cumulative Operation Time Selection
b5-28
PI Feedback Square Root Ac Function Selection
o3-02
Read Allowed Selection
-QUICK-
** Main Menu **
- - - - - - - - - - - - - -
Quick Setting
-QUICK-
Reference Source
- - - - - - - - - - - - - - - - - - - -
B1-01= 1
*1*
Terminals
“1”
x2
Содержание P7
Страница 1: ...P7 Drive User Manual Model P7U Document Number TM P7 01...
Страница 58: ...Electrical Installation 2 30...
Страница 74: ...Digital Operator 3 16...
Страница 84: ...Start Up 4 10 Notes...
Страница 144: ...Programming 5 60 Notes...
Страница 210: ...Capacity Related Parameters B 6 Notes...
Страница 238: ...Spare Parts F 4 Notes...
Страница 239: ...EMC Compatibility G 1 Appendix G EMC Compatibility EMC Compatibility G 2 Electromagnetic Compatibility EMC G 3...
Страница 244: ...EMC Compatibility G 6 Notes...