7 System Application
7.2 Internal User I/O Wiring Harness and Air Line
7-4
155556-1CD
HW0484963
VA1400
Fig. 7-2: Connectors for Internal User I/O Wiring Harness and Air Line
3BC
2BC
1BC
A
Connector for the internal user I/O wiring harness:
JL05-2A20-29SC (socket connector with a cap)
Prepare pin connector: JL05-6A20-29P
Exhaust port: B
PT3/8 with a pipe plug
Exhaust port: A
PT3/8 with a pipe plug
Air Inlet: A
PT3/8 with a pipe plug
Air Inlet: B
PT3/8 with a pipe plug
Connector for the internal user I/O
wiring harness: JL05-2A20-29PC (with a cap)
Prepare connector JL05-6A20-29S
View A
Power cable terminal
for arc weldingTS200CHM
Power cable terminal for arc welding
Recommended crimped terminal: R100-10
Cover (TCV-2001-04) is supplied.