1 Zeroing Function
1.2 Details on Zeroing Function
1-5
163471-1CD
HW1481050
MH50/MH50-35/MH80/
MS80 Zeroing
2. When using the CF card slot: Connect the communication interface
(REX-CF60) with the amplifier by using
the communication cable (C232N-915).
When using the USB slot
: Connect the communication interface
(REX-USB60F) with the amplifier by
using the communication cable
(C232N-915).
3. Connect the lead wire to the amplifier.
(Do not connect the sensor yet.)
The installation locations of the zeroing sensors for each axis are shown in
Fig. 1-4 “Installation Locations of the Zeroing Sensors”
Perform the zeroing operation for every axis by referring to the procedures
described in the following pages.
The appearance of parts and installation locations may vary for each
model. In this manual, details are described by using the figures of MH50.
Fig. 1-4: Installation Locations of the Zeroing Sensors
S-axis
L-axis
U-axis
R-axis
B-axis
T-axis