5
Basic Specifications
5.6 Alterable Operating Range
5-11
177010-1CD
HW1483759
MH215
II
5.6.3
Adjustment to the Pulse Limitation of S-Axis
Apply the Instruction for “DX200 Instructions chapter 8.17 Changing the
Parameter Setting (manual No. RE-CTO-A220)” as part of reference
materials for adjusting the programming pendant when modifying the
range of motion of S-Axis.
The limitation to the pulse (Pulse Soft Limit + 1st Axis ) : SICxG400
The limitation to the pulse (Pulse Soft Limit - 1st Axis ) : SICxG408
* Refer to
section 5.6 “Alterable Operating Range”
Degree
0
15
30
45
60
75
90
Number
of Pulse
0
35840
71680
107520
143360
179200
215040
Degree
105
120
135
150
165
180
(Standard)
Number
of Pulse
250880
286720
322560
358400
394240
430080
NOTE
Adjust both of the pulse limitation and the angle of S-Axis
mechanical stopper as modifying the range of motion for
machinery.
40 of 102