Powering Up GP8 EduCart
The GP8 EduCart is designed to run on 120 VAC, 15 amp circuit.
1. Double check the jumper is installed in the appropriate location on the
Step up/down transformer.
2. Plug the EduCart power strip into an independent 120 VAC, 15 amp
circuit and turn the power strip ON.
WARNING
• Read and follow all local and federal regulation when connecting
the EduCart to the required power sources.
Not reading and following all local and federal regulation when
connecting power source may cause death or serious injury.
YRC1000micro
ROBOT CONTROLLER
STU-1000
STEP UP & DOWN TRANSFORMER
110/120/220/240VAC, 1000 WATT
OUTPUT 220V
RECEPTACLE
240VAC
INPUT VOLTAGE SELECTOR
220VAC
200VAC
110VAC
COGNEX IN-SIGHT
MICRO CAMERA
NETGEAR GS308P
ETHERNET SWITCH
8 PORT,W/POE
220V POWER
RECEPTACLE
D
C
A
B
1
INTERFACE PANEL
W/24V POWER SUPPLY
OUTPUT 120V
RECEPTACLE
CN1
CA3031
CN4
X1
TR3020
CA5I010
CA5F410
PWS3E010
24VDC/5A
POWER STRIP
6 OUTLET
120VAC/15A
2
2
CA3100
PRX
19110
CLOSED
PRX
19080
OPEN
EGP
GRPR19010
GRIPPER
1BC
R1-1BC
CN3
JMACD-ASF30-1E
CN4
JMACD-ASF31-1E
X81
SMART
PENDANT
CA81
2
CN3
CA5Z071
2
SCN13D010
MICROSCAN3
SCANNER
CA13D011
TB1
CA3030
CA5Z070
PN (171393-1)
PN (185908-1)
GP IO
SAFETY
ROBOT GP8
LAN
YRC1000 MICRO (LAN)
NEXGEAR ETHERNET
8 PORT SWITCH
(OPTIONAL)
1
2
3
4
5
6
7
8
T-POWER AC TO
DC ADAPTER
OPTIONAL
VISION KIT
42 of 88