5
Alarm and Error
5.1 Alarm
5-8
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
4290
TPS:
ERROR
60
Err060
Sub code[60**] shows the error code of
Fronius power source
60 :main error code
** :sub error code
Confirm the Fronius's manual
61
ErrArc
Sub code[61**] shows the error code of
Fronius power source
61 :main error code
** :sub error code
Confirm the Fronius's manual
62
Err062
Sub code[62**] shows the error code of
Fronius power source
62 :main error code
** :sub error code
Allow the machine to cool
Confirm the Fronius's manual
63
EIF
Sub code[63**] shows the error code of
Fronius power source
63 :main error code
** :sub error code
Check interface configuration
Confirm the Fronius's manual
64
Errtf8
Sub code[64**] shows the error code of
Fronius power source
64 :main error code
** :sub error code
Change the thermo sensor of the
cooling unit
Confirm the Fronius's manual
65
hotH2O
Sub code[65**] shows the error code of
Fronius power source
65 :main error code
** :sub error code
Cool down the cooling liquid
Confirm the Fronius's manual
66
tJo
Sub code[66**] shows the error code of
Fronius power source
66 :main error code
** :sub error code
Allow the JobMaster torch to cool
Confirm the Fronius's manual
67
ErrtJo
Sub code[67**] shows the error code of
Fronius power source
67 :main error code
** :sub error code
Change JobMaster PC-board
Confirm the Fronius's manual
68
Err068
Sub code[68**] shows the error code of
Fronius power source
68 :main error code
** :sub error code
Confirm the Fronius's manual
Alarm
No.
Alarm
Name
Sub
Code
Meaning
Remedy
58 of 75