![YASKAWA Motoman DX200 Скачать руководство пользователя страница 18](http://html2.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_operators-manual_3227486018.webp)
2
Setup
2.3 Setting and Confirmation of Hardware Configuration
2-2
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
2.3
Setting and Confirmation of Hardware Configuration
2.3.1 Removing Unnecessary EW Board
The WELDCOM is connected to the welding power source using the
digital interface via Ethernet communication. This does not require the EW
board (YEW01, XEW02, etc.) for an analog interface, so remove the EW
board.
2.3.2 Station Number when EW Board is Left
A digital interface requires a virtual EW module, not an actual EW board.
The virtual EW module also has a station number. If leaving an EW board
unremoved for other welding power sources, set the actual EW board
station number so that it does not duplicate the virtual EW module station
number.
(Setting Example)
Replacing welding power source of analog interface with that of
digital interface
Remove the actual EW board, which will be unnecessary. (The station
number of the virtual EW module is set at the time of configuration.)
When connecting welding power source of digital interface as
Welder 1, and analog interface as Welder 2
Because the virtual EW module station number is set to the smallest
number at the time of configuration, set the EW board station number
to the second or later number.
SUPPLE-
MENT
In multiple robot systems, if some welding power source uses
digital interface and some uses analog interface, leave as
many EW boards as the necessary analog interfaces.
Welder1
YEW01
X100
YCP01
Digital I/F
Power Source
Virtual
EW
Virtual
EW
Station Number: 01
Station Number: 01
DX200
YCP21
YEW01
DX200
YCP21
Station Number: 02
Station Number: 01
Welder1
Analog I/F
Power Source
Welder2
Digital I/F
Power Source
Virtual
EW