2
Setup
2.5 System Configuration
2-14
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
Press [ENTER] to confirm the setting.
A confirmation dialog box appears. Select {YES}.
2.5.8 Setting of Parameter (When Welder is FroniusTPSi)
When the welder is FroniusTPSi, the following parameters should be set.
The register number to be set allows to check the welder status.
Bit0:Heartbeat Powersource
Bit1:Power source ready
Bit2:Arc stable
Bit3:Current flow
Bit4:Main current signal
Bit5:Torch collision protection
Bit6:Wire stick control
Bit7:Wire available
Bit8:Touched
Bit9:Torchbody connected
Bit10:Command value out of range
Bit11:Correction out of range
Bit12:Process active
Bit13~15:Reserved (Do not change.)
The register number to be set allows to operate the signals to the welder.
Bit7:Welding simulation
Bit8:Touch sensing
Bit9:Reserved
Bit10:SFI ON
Bit11:Synchropulse ON
Bit12:WireBreake
Bit13:Torch XChange
Bit14:TeachMode
Bit15:Reserved (Do not change.)
Parameter
Initial value
Name
AxP92
160
Status flag input register
Parameter
Initial value
Name
AxP93
161
Control flag input register
30 of 75