3
Operation of Welding Condition File Edit Window
3.13FroniusTPSi Type: Operation of Weld Parameter Setting Window
3-14
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
3.13
FroniusTPSi Type: Operation of Weld Parameter Setting
Window
1. At the top window, select {Set Parameter}.
– The parameter of the selected weld user file can be changed.
2. Select {Weld Parameter}.
Penetration stabilizer: Sets the allowable value of speed fluctuation in
fluctuating the wire feeding speed in order to stabilize the welding current.
It is available only when the welding mode is PMC or LSC.
Arc length stabilizer: Stabilizes welding even the amount of wire sticking
out for short circuiting arc varies or there is interference from the outside.
It is available only when the welding mode is PMC.
For details, see the user manual of the welding power source.
3. Select {Gas/Wire}.
Gas preflow: Pre-flow that the robot performs as approaching the
welding start point.
Gas postflow: Specify the time period of gas release performed at the
end of the welding.
46 of 75