7 Parameter Table
EN 42
YASKAWA Europe
TOEP C710606 50B - AC Drive L1000V - Quick Start Guide
S2-02/
S2-03
Slip Com-
pensation
Gain
Motoring /
Regen.
Mode
Set the slip compensation gain for
motoring operation (S2-02) and
during regenerative operation (S2-
03).
Induction Motor Auto-Tuning
T1-01
Auto-Tun-
ing Mode
Selection
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning
2: Stationary Auto-Tuning for
Line-to-Line Resistance
T1-02
Motor
Rated
Power
Sets the motor rated power as spec-
ified on the motor nameplate.
T1-03
Motor
Rated Volt-
age
Sets the motor rated voltage as
specified on the motor nameplate.
T1-04
Motor
Rated Cur-
rent
Sets the motor rated current as
specified on the motor nameplate.
T1-05
Motor Base
Frequency
Sets the rated frequency of the
motor as specified on the motor
nameplate.
T1-06
Number of
Motor Poles
Sets the number of motor poles as
specified on the motor nameplate.
T1-07
Motor Base
Speed
Sets the rated speed of the motor as
specified on the motor nameplate.
Monitor
Description
U1-01
Speed Reference (%)
U1-02
Output Speed (%)
U1-03
Output Current (A)
U1-05
Motor Speed (%)
U1-06
Output Voltage Reference (Vac)
U1-07
DC Bus Voltage (Vdc)
U1-08
Output Power (kW)
U1-09
Torque Reference (% of motor rated torque)
No.
Name
Description
U1-10
Displays the input terminal status.
U1-11
Displays the output terminal status.
U1-12
Verifies the drive operation status.
U1-16
Output Speed after Soft Starter
U1-18
oPE Fault Parameter
Fault Trace
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Speed Reference at Previous Fault
U2-04
Output Speed at Previous Fault
Monitor
Description
U1-10 = 0 0 0 0 0 0 0 0
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
1
1
1
1
1
1
1
1
U1-11 = 0 0 0 0 0 0 0 0
Multi-Function
Digital Output
(terminal MA-MB-MC)
Digital Output
(terminal MD-ME-MF)
Digital Output
(terminal P1-MC)
Multi-Function
Multi-Function
Not Used
1
1
1
Not Used
Not Used
Not Used
During run
During zero-speed
Down Direction
Fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
1
1
1
1
1
1
1
1
U1-12 = 0 0 0 0 0 0 0 0