7.2 Specifications and Ratings
7.2.9 Servomotor Derating Rates for Surrounding Air Temperatures
7
Specifications, Ratings, and Exter
nal Dimensions of SGM7G Servomotors
7-9
7.2.9
Servomotor Derating Rates for Surrounding Air Tem-
peratures
Apply a suitable derating rate from the following graphs according to the surrounding air tem-
perature of the Servomotor (60°C max.).
When using Servomotors with derating, change the overload warning and overload alarm
detection timing in advance based on the overload detection level of the motor. Refer to the fol-
lowing section for the overload detection level of the motor.
7.2.6 Servomotor Overload Protection Characteristics
Note: 1. Use the combination of the SERVOPACK and Servomotor so that the derating conditions are satisfied for
both the SERVOPACK and Servomotor.
2. The derating rates are applicable only when the average motor speed is less than or equal to the rated
motor speed. If the average motor speed exceeds the rated motor speed, consult with your Yaskawa rep-
resentative.
7.2.10
Applications Where the Altitude of the Servomotor
Exceeds 1,000 m
The Servomotor ratings are the continuous allowable values at an altitude of 1,000 m or less. If
you use a Servomotor at an altitude that exceeds 1,000 m (2,000 m max.), the heat dissipation
effect of the air is reduced. Apply the appropriate derating rate from the following graphs.
When using Servomotors with derating
, change the overload warning and overload alarm detec-
tion timing in advance based on the overload detection level of the motor. Refer to the following
section for the overload detection level of the motor.
7.2.6 Servomotor Overload Protection Characteristics
Note: 1. Use the combination of the SERVOPACK and Servomotor so that the derating conditions are satisfied for
both the SERVOPACK and Servomotor.
2. The derating rates are applicable only when the average motor speed is less than or equal to the rated
motor speed. If the average motor speed exceeds the rated motor speed, consult with your Yaskawa rep-
resentative.
0
10
20
30
40
50
60
70
0
20
40
60
80
100
120
0
20
40
60
80
100
120
SGM7G-09, 13, and 20
0
10
20
30
40
50
60
70
SGM7G-03 and 05
0
20
40
60
80
100
120
0
10
20
30
40
50
60
70
SGM7G-75
SGM7G-75
SGM7G-1E
SGM7G-1E
SGM7G-30 and -44
SGM7G-30 and -44
SGM7G-55 and -1A
SGM7G-55 and -1A
Derating rate (%)
Derating rate (%)
Derating rate (%)
Surrounding air temperature (°C)
Surrounding air temperature (°C)
Surrounding air temperature (°C)
0
500
1000
1500
2000
2500
0
20
40
60
80
100
120
0
500
1000
1500
2000
2500
0
20
40
60
80
100
120
SGM7G-09, -13, and -20
SGM7G-03 and -05
0
500
1000
1500
2000
2500
0
20
40
60
80
100
120
SGM7G-55, -75, -1A, and -1E
SGM7G-30 and -44
Altitude (m)
Derating rate (%)
Altitude (m)
Derating rate (%)
Altitude (m)