10 CC-Link Code Numbers
50
YASKAWA ELECTRIC
SIEP C730600 83D YASKAWA AC Drive Option SI-C3 Technical Manual
124H
(1017H)
Fault contents 5
–
0
Excessive PID feedback (FbH)
0041H
1
External fault (input terminal S1) (EF1)
0042H
2
External fault (input terminal S2) (EF2)
0043H
3
Mechanical weakening detection 1 (oL5)
0044H
4
Mechanical weakening detection 2 (UL5)
0045H
5
Current offset fault (CoF)
0046H
6, 7
Reserved
–
8
DriveWorksEZ fault (dWFL)
0049H
9 to B
Reserved
–
C
Output Voltage Detection Fault (voF)
–
D
Braking Resistor Fault (rF)
–
E
Braking Transistor Overload Fault (boL)
–
F
Reserved
–
130H
(101CH)
CPF contents 1
–
0, 1
Reserved
–
2
A/D conversion error (CPF02)
0083H
3
PWM data error (CPF03)
0084H
4, 5
Reserved
–
6
EEPROM data error (CPF06)
0087H
7
Terminal board communication error (CPF07)
0088H
8
EEPROM serial communication fault (CPF08)
0089H
9, A
Reserved
–
B
RAM fault (CPF11)
008CH
C
Flash memory fault (CPF12)
008DH
D
Watchdog circuit exception (CPF13)
008EH
E
Control circuit fault (CPF14)
008FH
F
Reserved
–
131H
(101DH)
CPF contents 2
–
0
Clock fault (CPF16)
0091H
1
Timing fault (CPF17)
0092H
2
Control circuit fault (CPF18)
0093H
3
Control circuit fault (CPF19)
0094H
4
Hardware fault at power up (CPF20)
0095H
5
Hardware fault at communication start up (CPF21)
0096H
6
A/D conversion fault (CPF22)
0097H
7
PWM feedback fault (CPF23)
0098H
8
Drive capacity signal fault (CPF24)
0099H
9
Reserved
–
A
Control Circuit Fault (CPF26)
009BH
B
Control Circuit Fault (CPF27)
009CH
C
Control Circuit Fault (CPF28)
009DH
D
Control Circuit Fault (CPF29)
009EH
E
Control Circuit Fault (CPF30)
009FH
F
Control Circuit Fault (CPF31)
00A0H
132H
(101EH)
CPF contents 3
–
0
CPF32 Control Circuit Fault
00A1H
1
CPF33 Control Circuit Fault
00A2H
2
CPF34 Control Circuit Fault
00A3H
3 to F
Reserved
–
Extended Command
Code
(Monitor Code)
Fault Name
Fault Code (U2, U3)
BIT