10 CC-Link Code Numbers
54
YASKAWA ELECTRIC
SIEP C730600 83D YASKAWA AC Drive Option SI-C3 Technical Manual
Energy-Saving Unit Monitor Codes
Table 35 Energy-Saving Unit Monitor Codes
132H
–
CPF contents 3
160H
–
DC bus voltage feedback
161H
–
DC voltage reference
162H
–
DC current reference
163H
–
Power supply side power
164H
–
Power supply side current
–
280H
DC bus voltage reference
–
281H
Active current limit (positive)
–
282H
Active current limit (negative)
1181H
2181H
Read and write Run command source
0: LED keypad
1: Control circuit terminals (sequencer input)
2: MEMOBUS/Modbus communications
3: Option card
1179H
2179H
Read and write voltage reference source
0: Keypad
1: Control circuit terminals (analog input)
2: MEMOBUS/Modbus communications
3: Option PCB
7: Input voltage based control 1
8: Input voltage based control 2
<1> Refer to
Energy-Saving Unit Fault Contents on page 55
Energy-Saving Unit Alarm Contents on page 58
for information on fault contents.
<2> Terminals will differ depending on the model of the drive. Refer to
Terminals that Change depending on the Model of the Drive on page 37
for information on terminals.
Monitor Code
Name
Comments
0000H to 0006H
Reserved
–
0007H
DC bus voltage reference (before
SFS)
Units: 1 V
0008H
DC bus voltage feedback
Units: 1 V
0009H to 00CH
Reserved
–
000DH
Power supply side power
Units: 1 kW
000EH
DC bus side power
Units: 1 kW
000FH
Input terminal status
0010H
Output terminal status
0011H to 0017H
Reserved
–
0018H
Active current
Units: 0.1%
0019H
Reserved
–
0034H to 0036H
Reserved
–
Command Code
Name
Read
Write
BIT
7
6
5
4
3
2
1
0
Multi-Function Digital Input 1 (terminal S1 enabled)
Multi-Function Digital Input 2 (terminal S2 enabled)
Multi-Function Digital Input 3 (terminal S3 enabled)
Multi-Function Digital Input 4 (terminal S4 enabled)
Multi-Function Digital Input 5 (terminal S5 enabled)
Multi-Function Digital Input 6 (terminal S6 enabled)
Multi-Function Digital Input 7 (terminal S7 enabled)
Multi-Function Digital Input 8 (terminal S8 enabled)
1: ON
RW
0: OFF
7
6
5
4
3
2
1
0
Multi-Function Digital Output (terminal M1-M2) enabled
Multi-Function Digital Output 1 (terminal P1) enabled
<1>
Multi-Function Digital Output 2 (terminal P2) enabled
<1>
Fault Contact Output (terminal MA/MB-MC) enabled
1: ON
RW
0: OFF
Not used