4 Specifications and External Dimensions for
Σ
-V-SD Drivers
4.2.2 External Dimensions
4-16
(2) SERVOPACK for Two Axes
∗
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
4-M5 Screw Holes
SERVOPACK
Rear View
Through Hole
365
±
0.5(Mounting Pitch)
Mounting Hole Diagram
(Mounting Pitch)
Model
Number
Input Voltage
4-6 Dia.
Ground
Terminal
M4 Screws
Nameplate
Cooling Fan
Air Flow
Air Flow
Heat Sink
Unit: mm
338
B
±
0.5
380
10
C
D
A
15.5
7.5
380
7.5
(10)
B
A
10
(7.5)
365
(145)
300
CN18
CN28
200
5
(100)
23
(15)
E5
(F)
334
(23)
∗
∗
(115
°
)
(135
°
)
Model
A
B
C
D
E
F
Approx.
Mass (kg)
CACR-JUM23ACA
50
30
4
42
40
(5)
4.5
CACR-JUM24ACA
50
30
4
42
40
(5)
4.5
CACR-JUM25ACA
75
55
5
65
63
(7)
5.7
CACR-JUM23DCA
75
55
5
65
63
(7)
5.2
CACR-JUM24DCA
75
55
5
65
63
(7)
5.2
CACR-JUM25DCA
75
55
5
65
63
(7)
5.7