8 Operation
8.7.4 Absolute Encoder Setup
8-30
Procedure for Setup
Follow the steps below to setup the absolute encoder.
1.
Make sure that the motor power is OFF.
2.
In the SigmaWin for
Σ
-V-SD (MT) component main window, click
Setup
, point to
Set Absolute
Encoder
and click
Reset Absolute Encoder
. A warning message appears confirming if you
want to continue the processing.
Click
Cancel
to return to the main window without resetting the absolute encoder.
3.
Click
Continue
, and the Absolute encoder Setup box appears.
The Alarm Name box displays the code and name of the alarm that is occurring now.
4.
Click
Execute setting
, and a verification message appears confirming if you want to continue
although the coordinate system will change.
Click
Cancel
to return to the previous window without resetting the absolute encoder.