![YASKAWA AI-A3 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/yaskawa/ai-a3/ai-a3_installation-manual_907045044.webp)
6 Related Parameters
44
YASKAWA ELECTRIC
TOBP C730600 78D YASKAWA AC Drive Option AI-A3 Installation Manual
F2-08
(3164)
Terminal V2 Signal Level Select
Sets the input signal level for MFAI terminal
V2.
0: 0 V to 10 V
1: -10 V to 10 V
2: 4 mA to 20 mA
Default: 0
Range: 0 to 2
F2-09
(3165)
Terminal V2 Function Selection
Sets the function for MFAI terminal V2.
Default: F
Range: 4 to 2D
F2-10
(3166)
Terminal V2 Gain Setting
Sets the gain of the analog signal input to
MFAI terminal V2.
Default: 100.0%
Min: -999.9
Max: 999.9
F2-11
(3167)
Terminal V2 Bias Setting
Sets the bias of the analog signal input to
MFAI terminal V2.
Default: 0.0%
Min: -999.9
Max: 999.9
F2-12
(3168)
Terminal V3 Signal Level Select
Sets the input signal level for MFAI terminal
V3.
0: 0 V to 10 V
1: -10 V to 10 V
2: 4 mA to 20 mA
Default: 0
Range: 0 to 2
F2-13
(3169)
Terminal V3 Function Selection
Sets the function for MFAI terminal V3.
Default: F
Range: 4 to 2D
F2-14
(316A)
Terminal V3 Gain Setting
Sets the gain of the analog signal input to
MFAI terminal V3.
Default: 100.0%
Min: -999.9
Max: 999.9
F2-15
(316B)
Terminal V3 Bias Setting
Sets the bias of the analog signal input to
MFAI terminal V3.
Default: 0.0%
Min: -999.9
Max: 999.9
H3-02
(434)
Terminal A1 Function Selection
Selects the function assigned to analog input
terminal A1.
Default: 0
Range: 0 to 32
H3-03
(411)
RUN
Terminal A1 Gain Setting
Sets the level of the selected input value that is
equal to 10 Vdc input at terminal A1 (gain).
Default: 100.0%
Min: -999.9
Max: 999.9
H3-04
(412)
RUN
Terminal A1 Bias Setting
Sets the bias of the analog signal to be input to
the multi-function analog input terminal A1.
Default: 0.0%
Min: -999.9
Max: 999.9
H3-06
(414)
Terminal A3 Function Selection
Selects the function assigned to analog input
terminal A3.
Default: 2
Range: 0 to 32
H3-07
(415)
RUN
Terminal A3 Gain Setting
Sets the gain of the analog signal to be input to
the multi-function analog input terminal A3.
Default: 100.0%
Min: -999.9
Max: 999.9
H3-08
(416)
RUN
Terminal A3 Bias Setting
Sets the bias of the analog signal to be input to
the multi-function analog input terminal A3.
Default: 0.0%
Min: -999.9
Max: 999.9
No.
(Hex.)
Name
Description
Values
GEM_IO_conditional_E - コピー.fm 44 ページ 2022年1月19日 水曜日 午前9時56分