![YASKAWA AI-A3 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/yaskawa/ai-a3/ai-a3_installation-manual_907045043.webp)
6 Related Parameters
YASKAWA ELECTRIC
TOBP C730600 78D YASKAWA AC Drive Option AI-A3 Installation Manual
43
Parameter Table
“RUN” indicates that the parameter can be changed during run.
Note:
Hex.: MEMOBUS addresses that you can use to change parameters over network
communication are represented in hexadecimal numbers.
Table 6 Related Parameters
No.
(Hex.)
Name
Description
Values
b1-01
(180)
Reference 1 Source
Selects the input method for frequency
reference.
0: Keypad
1: Analog Input
2: Memobus/Modbus Communications
3: Option PCB
4: Pulse Train Input
Default: 1
Range: 0 to 4 (Set to 3)
F2-01
(38F)
Analog Input Function Selection
Determines how the input terminals on the
option are to be used.
0: 3 Independent Channels
1: 3 Channels Added Together
2: 3 Additional Channels
Default: 0
Range: 0, 1, 2
F2-02
(368)
RUN
Analog Input Option Card Gain
Sets the gain for the input signal to the analog
card.
Default: 100.0%
Min: -999.9
Max: 999.9
F2-03
(369)
RUN
Analog Input Option Card Bias
Sets the bias for the input signal to the analog
card.
Default: 0.0%
Min: -999.9
Max: 999.9
F2-04
(3160)
Terminal V1 Signal Level Select
Sets the input signal level for MFAI terminal
V1.
0: 0 V to 10 V
1: -10 V to 10 V
2: 4 mA to 20 mA
Default: 0
Range: 0 to 2
F2-05
(3161)
Terminal V1 Function Selection
Sets the function for MFAI terminal V1.
Default: F
Range: 4 to 2D
F2-06
(3162)
Terminal V1 Gain Setting
Sets the gain of the analog signal input to
MFAI terminal V1.
Default: 100.0%
Min: -999.9
Max: 999.9
F2-07
(3163)
Terminal V1 Bias Setting
Sets the bias of the analog signal input to
MFAI terminal V1.
Default: 0.0%
Min: -999.9
Max: 999.9
GEM_IO_conditional_E - コピー.fm 43 ページ 2022年1月19日 水曜日 午前9時56分