DOUBLE INSULATION

Double insulation is a concept in safety in electric power tools, which eliminates the need 

for the usual three-wire grounded power cord. All exposed metal parts are isolated from 

the internal metal motor components with protecting insulation. Double-insulated tools 

do not need to be grounded.

ELECTRICAL CONNECTION
This product has a precision-built electric motor. It should be connected to a power 

supply that is 120 V, AC only (normal household current), 60 Hz. 
Do not operate this product on direct current (DC). A substantial voltage drop will cause a 

loss of power and the motor will overheat. If your product does not operate when plugged 

into an outlet, double-check the power supply.

GFCI
Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit(s) 

or outlet(s) to be used for the product.Receptacles are available having built-in GFCI 

protection and may be used for this measure of safety.

GUIDELINES FOR USING EXTENSION CORDS
USE THE PROPER EXTENSION CORD. Make sure your extension cord is in good 

condition. When using an extension cord, be sure to use one heavy enough to carry the 

current your product will draw. An undersized cord will cause overheating. The table 

below shows the correct size to use depending on cord length and nameplate ampere 

rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the 

heavier the cord.

Note:

 Servicing of a product with double insulation requires 

extreme care and knowledge of the system and should be 

performed only by a qualified service technician. Take the 

unit to a qualified service dealer for inspection and possible 

repair using only identical replacement parts.

!

 

WARNING: 

The double insulated system is intended 

to protect the user from shock resulting from a break 

in the tool’s internal insulation. Observe all normal 

safety precautions to avoid electrical shock.

Electrical Inf

ormation

Electrical Inf

ormation

!

 

WARNING: 

Check extension cords before each use. 

If damaged replace immediately.

Never use product with a damaged cord since 

touching the damaged area could cause electrical 

shock resulting in serious injury.

!

 

WARNING: 

ALTHOUGH THIS TOOL IS DOUBLE 

INSULATED, THE EXTENSION CORD AND RECEPTACLE 

MUST STILL BE GROUNDED WHILE IN USE TO PROTECT 

THE OPERATOR FROM ELECTRICAL SHOCK.

Make sure your extension cord is properly wired and in good electrical condition. Always 

replace a damaged extension cord or have it repaired by a qualified person before use.

Keep extension cords away from sharp objects, excessive heat and damp or wet areas.

Use a separate electrical circuit for your tools. This circuit should comprise a wire 

of at least 12 gauge and should be protected with a 15 A time-delayed fuse. Before 

connecting the motor to the power line, make sure the switch is in the OFF position and 

the electric current is identical to that stamped on the motor nameplate. Running at a 

lower voltage will damage the motor.

Minimum Gauge for Extension Cords (AWG)

(when using 120 V only)

Ampere Rating

Total Length of Cord in Feet (metres)

More Than Not More Than

25' (7.6 m)

50' (15 m)

100' (30.4 m)

150' (45.7 m)

0

6

18

16

16

14

6

10

18

16

14

12

10

12

16

16

14

12

12

16

14

12

Not Recommended

Содержание AERO FORCE 060-3775-4

Страница 1: ...6 523 5218 IMPORTANT Read and follow all safety rules and operating instructions before using this product Instruction Manual LEAF BLOWER VAC WITH AERO FORCE TECHNOLOGY 3084514 Conforms to UL STD 1017...

Страница 2: ...f electric shock if your body is grounded Don t expose power tools to rain or wet conditions store indoors Water entering a power tool will increase the risk of electric shock Do not handle plug or to...

Страница 3: ...the cord Use only identical manufacturer s replacement parts and accessories Use of any other parts may create a hazard or cause product damage In a double insulated appliance two systems of insulati...

Страница 4: ...comply with ANSI Z87 1 along with hearing protection Wet Conditions Alert Do not expose to rain or use in damp locations Symbol Name Designation Explanation Keep Bystanders Away Keep all bystanders a...

Страница 5: ...requires extreme care and knowledge of the system and should be performed only by a qualified service technician Take the unit to a qualified service dealer for inspection and possible repair using on...

Страница 6: ...the product and any accessories from the box Make sure that all items listed in the packing list are included Inspect the product carefully to make sure no breakage or damage occurred during shipping...

Страница 7: ...bled vacuum tube properly aligned insert into aligned gate opening and lock vacuum tube into place Make certain the vacuum tube aligning tab is firmly seated before locking the latch Fig 4 Assembly Wh...

Страница 8: ...rd through the side of the loop located on the rear of the blower housing and place underneath the cord retainer Fig 7 A Cord retainer B Loop C Plug D Extension cord A C B D OPERATING THE BLOWER To ke...

Страница 9: ...rd or cause product damage Always wear eye protection with side shields marked to comply with ANSI Z87 1 along with hearing protection Failure to do so could result in objects being thrown into your e...

Страница 10: ...is unplugged 1 Check cord to make sure it is plugged into an electrical outlet 2 Power speed switch is in the OFF position 2 Slide switch to high or low 3 Defective power switch 3 Call toll free helpl...

Страница 11: ...s not cover 1 Any part that has become inoperative due to misuse commercial use abuse neglect accident improper maintenance or alteration 2 The unit if it has not been operated and or maintained in ac...

Страница 12: ...Made in China Imported by Yardworks Canada Toronto Canada M4S 2B8...

Отзывы: