10
Operating
Manual
YZ-X9
11. When the staff leave the machine, please park the machine on a level
ground and take out the key.
12. After cleaning, perform daily maintenance procedures (refer to "Machine
Maintenance").
Battery gauge
The battery charge gauge will display the battery charge. When the battery is
fully charged, all indicator lights are on. As power is consumed, refer to
The indicator lights will turn off from right to left. In order to prolong the life of
the battery, please do not let the indicator light go out below the following
power consumption.
Note: In order to extend the life of the battery, please be sure to charge the
battery after the total usage time of the machine exceeds 30 minutes.
Water tank drainage
The sewage tank should be drained and cleaned after each use. The clean water
tank should be cleaned regularly to remove any corroded parts. Transport the
machine
Go to the drainage location, turn off the power key, and perform drainage
according to the following drainage instructions: For safety: leave or repair the
machine
Before, please park the machine on a level ground, turn off the machine and take
out the key. Wastewater tank
1. Unscrew the cover of the sewage tank drain pipe counterclockwise and remove
it
2. Open the recovery tank cover, and then rinse the water tank
3. Remove and rinse the floating filter located in the sewage tank.
Battery charging
Note: In order to extend the life of the battery and ensure the best performance
of the machine, the machine must be used for at least 30 minutes
Only above can the battery charge. Do not leave the battery uncharged for a
long time. The following charging instructions apply to this machine
The included charger. Please be sure to use the charger with the following
specifications to avoid battery damage. Battery charger specifications:
* Charger type:-Charger for lead-acid battery
* Output voltage-36 volts
* Output current-25 ampere
* Automatic power-off circuit
* Suitable for deep cycle battery charging