Страница 1: ...OPERATION MANUAL Digital Platform Scale DP 5601 Digital Indicator EDI 561 Read this manual and keep it handy Yamato Scale Co Ltd EXPORT 1302 ...

Страница 2: ...code number 10 How to add and total 11 12 1 How to carry out manual addition 2 1 How to carry out automatic addition 2 2 How to return to manual addition How to cancel addition 13 1 How to cancel last addition 2 How to subtract weight How to use the TOTAL key 14 How to register the entries 15 17 1 How to register the entries collectively 2 How to register the entries individually How to call regis...

Страница 3: ...roperty Caution Denotes a potential risk that may result in injury or damage on the equipment if operated without compliance with this sign Inhibition Denotes what is inhibited Compulsion Denotes what must be followed NOTE Prior to use read carefully the following descriptions of Danger Warning and Caution to understand and comply with them Danger To avoid electrical shock 1 Ground the instrument ...

Страница 4: ...trument at temperature between 10C and 40C 5 Work on the level place If not level adjust the leveling legs Storage and Disposition STORING PLACE 1 Do not store the equipment in the place with high temperature humidity or receiving direct sunlight for a long period of time It should also be noted that substantial changes in the ambient temperature may cause condensation inside the equipment resulti...

Страница 5: ...meric keys and the key The weight of the container must be measured in advance 9 e A registered tare value can be set using the key The weight of the container must be measured and registered in advance 15 Addition and total Use this function when you wish to know the number of times measurement values are added as well as the total weight c Addition and total display can be performed using the an...

Страница 6: ...Do not place the instrument in a location exposed to direct sunlight or exposed to direct air blow from air conditioning equipment etc Do not push the display section or the operation key section with a pointed object The instrument must be leveled correctly Adjust its levelness with the leveling leg so that the air bubble in the spirit level is located inside the red circle at the center of the l...

Страница 7: ... mount brackets d set in the above step 1 hook the brackets onto the 2 wooden tapping screws f set in the above step 2 The installation is now complete Caution Since the 4 set screws c have been tightened to a fixed torque at the factory the enclosure is water proof and dust proof i e IP66 protection rating easy to wash and hygienically sound HACCP compliance However for the wall mount type indica...

Страница 8: ...6 Display and operation key sections ...

Страница 9: ...splay or resets to zero Turns the power OFF Calls registered data or registers data Performs the quick tare subtraction Manual addition or printout at addition Subtraction or printout at subtraction Totalizing or total printout To set code number Determines the setting value entered to Enters a numerical value Clear data entry or tare Change of function on keys 2 to 8 Feed the print paper with key...

Страница 10: ...platform of the instrument The weight of the object appears The following indication shows that the object weighs 10 00 kg If the error code appears after an object is placed on the instrument the weight of the object exceeds the measurable range of the instrument Remove the object from the instrument and use the instrument within its rated operating range How to power OFF Operating procedure Pane...

Страница 11: ...comes on e Weighing start Place an object to be weighed in the container The net weight of the object appears 2 Preset tare when tare weight is already known Use the numeric keys and key Example To set the tare weight to 1 50 kg Operating procedure Panel display Remarks Entering the tare weight Enter and in that order Press the key The auxiliary display returns to normal indication On the main dis...

Страница 12: ...00 appears and the NET lamp goes out How to enter a code number Example To enter 123456 as the code number Operating procedure Panel display Remarks c Press the key The blinking field is used for setting a value d Entering the code number Enter and in that order Up to 6 digits can be entered If you enter the wrong number press the key and then enter the correct number e Press the key ...

Страница 13: ... of the object appears d Addition Press the key with the object placed To cancel the addition press the key There is no change in the indication If the parameter number 035 is set to any numbers other than 0 SEnd appears for the preset seconds If the total value has exceeded the storage capacity of the internal memory after addition the following error codes appear The number of Measurement times ...

Страница 14: ... preset seconds If the total value has exceeded the storage capacity of the internal memory after addition the following error codes appear The number of measurement times has exceeded The total weight has exceeded e Remove the object from the platform The display returns to 0 00 f One cycle of automatic addition is now complete By repeating Steps d to e each measurement value is added to the inte...

Страница 15: ... after addition If the parameter number 035 is set to any numbers other than 0 SEnd appears for the preset seconds The last addition weight is canceled regardless of the displayed weight 2 How to subtract weight Operating procedure Panel display Remarks c Place weighing items you desire to subtract on platform after addition The display shows the weight of items d Press the key The display remains...

Страница 16: ...y again The upper 3 digits of the total weight are displayed e Press the key again to show the total number of measurement times Maximum total number of measurement times is 4 digits Press the key The display returns to normal indication Continue to carry out the cycle of addition To end the addition and clear the total values z To clear the memory of the total values press the key while the total...

Страница 17: ...e Panel display Remarks c Enter and set all the data in advance Only the preset data can be registered If there are any measured objects on the platform of the instrument after data setting remove them from the platform d Press and hold the key The blinking field is used for setting a value This key works only when GROSS is zero i e there is nothing on the weighing unit e Press the key The blinkin...

Страница 18: ... them from the platform d Registration Press and hold the key The blinking field is used for setting a value This key works only when GROSS is zero i e there is nothing on the weighing unit e Entering a call number Enter and in that order f Press the key The display returns to normal indication Example To register a code number of 123456 in the call number 24 Operating procedure Panel display Rema...

Страница 19: ...ered data from the call number 70 which was registered in the previous section Operating procedure Panel display Remarks c Press the key This key works only when GROSS is zero i e there is nothing on the weighing unit The setting value blinks d Enter and in that order Enter a call number whose data you wish to display e Press the key Call number 70 Tare weight 0 00 kg Code number 000000 Call numbe...

Страница 20: ...t contents available A separate model of this printer which can be installed away from the indicator is also available For details refer to the dedicated instruction manual If RS232C I O is used The RS232C I O can be used for various data inputs and outputs operation commands and other purposes This is useful for the system management of weighing operations For details refer to the dedicated instr...

Страница 21: ...ss the key The screen returns to the weighing display Enter the day month and year in 2 digits each Example 10 03 01 e Time setting After press the key press the key The example shows 8 20 The ten s place of the hour blinks The time is shown in 24 hour format hour minute Specify the hour in 24 hour format f Using the numeric keys enter the hours and minutes in that order After entry press the key ...

Страница 22: ...g mode d Press the key until the parameter number whose setting you wish to change appears Pressing the key decreases the parameter number The setting value blinks Keep pressing the key automatically cycles through the parameters in the forward direction The key has the same function only goes backward e Using the numeric keys change the setting Press the key The setting value blinks If you enter ...

Страница 23: ...DO NOT CHANGE 035 SEnd DISPLAY TIME 000 001 NO SEnd DISPLAYED AT ADDITION PRINTER TPS 503W 001 008 SEnd DISPLAYED FOR SPECIFIED SECONDS AT ADDITION 053 LCD CONTRAST 125 DO NOT CHANGE 054 NOT USED 000 DO NOT CHANGE 055 NOT USED 005 DO NOT CHANGE 056 NOT USED 000 DO NOT CHANGE 058 AUTO POWER ON 000 000 NOT POWER ON AT PLUG IN 001 POWER ON AT PLUG IN 059 AUTO CALL AT POWER ON 000 000 NO FUNCTION 001 ...

Страница 24: ... 000 DO NOT CHANGE 073 NOT USED 000 DO NOT CHANGE 074 NOT USED 001 DO NOT CHANGE 086 000 000 CANCEL LAST MINUTE ADDITION DATA 001 SUBTRACT WEIGHT ON PLATFORM FROM SCALE MEMORY 092 NEGATIVE COUNT 000 000 NO MANUAL ADDITION OR NO OVER UNDER JUDGMENT WHEN THE NET WEIGHT IS NEGATIVE 001 MANUAL ADDITION OR OVER UNDER JUDGMENT ONLY WHEN THE NET WEIGHT IS NEGATIVE 002 MANUAL ADDITION OR OVER UNDER JUDGME...

Страница 25: ...lays this sign during operation Removing the object returns to the weighing display Use the instrument within its rated operating range Removing the platform of the instrument displays this sign during operation Correctly install the platform The panel shows 0 00 and the instrument is operational When the number of measurement times added has reached the maximum number 9999 further addition of the...

Страница 26: ...ess the key to reset the error and then restart communication When the optional RS232C is in use This code appears when the connected equipment transmits too many data Divide the transmission data of the connected equipment into two parts and then transmit each part separately Alternatively reduce the volume of the transmission data Press the key to reset the error and then restart communication T...

Страница 27: ...ppears when a USB flash drive for writing is not connected Check that a USB flash drive has been inserted Press the key to reset the error and then restart communication When the optional USB flash drive feature is used This code appears when there is no free space left in the USB flash drive for writing Check the free space of the USB flash drive Press the key to reset the error and then restart ...

Страница 28: ...tor lights at stable Automatic Indicator lights in automatic mode Shift Indicator lights when key is pressed Lamp indication Net Red LED lights during tare subtraction Total Red LED lights during total being displayed 7 Keys Turns on display or resets to zero Turns the power OFF Calls registered data or registers data Performs the quick tare subtraction Addition or printout at addition Subtraction...

Страница 29: ... device USB Memory PC etc Output data Date Code Gross weight Net weight Tare Total weight Times of addition Input data Addition command Total command Tare command Zero reset command Code Date Tare c Relay input output Output 6 outputs available Underweight Pre lower limit Acceptable weight Overweight Rough feed Fine feed Input Tare Zero reset Addition Total d USB Memory e Wireless communication 11...

Страница 30: ... 300 600 300 600 1200 1200 1500 2000 A 350 350 500 500 850 1200 B 300 500 750 750 1000 1200 C 80 0 10 112 0 20 148 0 20 236 0 30 236 0 50 246 0 50 D 270 270 400 400 720 1070 E 305 495 660 660 855 1070 F φ38 φ70 φ70 φ75 φ75 φ75 G Pole type 556 0 10 903 0 20 910 0 20 935 0 30 935 0 50 nil H Pole type 370 683 896 895 1145 nil Separate Type Standard Integrated Pole Type ...

Страница 31: ...29 Desk top Type Separate Stand Type ...

Страница 32: ...30 YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5562 PRINTED IN JAPAN ...