9
2. Before operating the Equipment
Precautions when installing the Equipment
2.For Ventilation
When the product is used (with the damper opened) for ventilation, take such measures as to
ensure sufficient ventilation around the installation location. When ventilation around the product
is not sufficient, hot air discharged through the exhaust port may cause increase in temperature
of the location or fume and gas generated from the sample may fill the space. Be sure to connect
the exhaust duct to the exhaust port to ensure discharge of hot air to the outside. The exhaust
duct is optionally av
ailable and should be ordered separately. See “P. 70 List of Accessories.”
3. Install the Equipment on leveled location.
Install this Equipment on leveled floor. If it is installed on rough and/or slope floor, vibration or
noise will be occurred, and unexpected trouble and malfunction may be happened.
Weight of this Equipment is as follows:
DNF811: approx. 135kg
、
DNF911 : approx. 210kg
Use cargo handling equipment for carrying and installation. Two or more people shall be
necessary when transporting by humans. In such an event, raise the adjuster and transport
slowly and gently.
4. Implement safety measures when installing the unit.
May be injured by moved and/or fallen this Equipment down by earthquake and/or unexpected
impact. Recommend to install this Equipment at the place away from the access door and to
take other safety steps.
5.
Implement appropriate safety measures after installation.
May be injured by moved and/or fallen this
Equipment
down
by
earthquake
and/or
unexpected impact.
To ensure the safety, be sure to provide any
adequate measur to the main body and to the
installation
surface
to
prevent
overturn.
DNF811/911 provide 2 adjusters underneath
front bottom of this Equipment.
Set those adjusters by the following procedure
after this Equipment installation.
①
Turn each adjuster until securely sand on the
floor.
②
Check any gap between floor and 4(four)
standing points.
③
Tighten each nut of its adjuster against to the
nut above to prevent loosening.
6. Ventilate sufficiently for the Equipment
Do not operate the Equipment blocked in the radiating slit holes-Louver on its side and back
pan
els and top panel. Refer to 3. “Name and Functions of each part” on page 11 for the location
of Louvers.
Internal temperature will rise, causing a malfunction of the controller to compromise the
performance as well as to cause a possible accident or a fire.
7. Do not operate at the location of liquid splashing.
Do not operate this Equipment at the location of liquid splashing. If Controller of this Equipment
will be wetted by splashing any kind of liquid, it may cause accident, controller malfunction,
electrical shock and/or fire.