Fish Analyzer

Fish Analyzer

TM

PRO [DFA110]

Operation Manual

Yamato Scale Co., Ltd.

● Please read this manual before using the device for correct use and keep it with you at all

times for later reference.

Introduction

Thank you for purchasing the Fish Conditioner Fish Analyzer

TM

or the Fish Analyzer

TM

PRO. Please read

this manual carefully for proper use and it is our hope that it can help improve the fish quality for your
business or your organization.

Yamato Scale Co., Ltd.

Содержание DFA110

Страница 1: ...rect use and keep it with you at all times for later reference Introduction Thank you for purchasing the Fish Conditioner Fish Analyzer TM or the Fish Analyzer TM PRO Please read this manual carefully for proper use and it is our hope that it can help improve the fish quality for your business or your organization Yamato Scale Co Ltd ...

Страница 2: ...iculture Forestry and Fisheries Policy and Development of quality measurement equipment aiming at improvement of fish prices and provision of high quality marine products and fish processing products The result of our collaboration and development was the Fish Analyzer TM Pro We are proud to bring to market the Fish AnalyzerTM Pro that can measure the fish fat content and fish freshness of horse m...

Страница 3: ... to hold and place the device on the fish for accurate measurement 15 Taking Measurements 16 See results from past measurements 16 Determining Fish Freshness Fish Status 18 Options and usage 19 Fish species selection 19 Energy saving mode for longer battery life 20 Display the average value 21 Limitations of Fish Fat measurements 21 Evaluation of measured result 22 Evaluation by impedance mode 22 ...

Страница 4: ...not recommend Indicates things to be enforced Before use please read Danger Warning and Caution carefully and comply accordingly Danger Preventing electric shock accidents Do not remove any screw on the back of the housing case Preventing from explosion or fire accident This device does not have non explosion features Do not use the device where flammable gas or hazardous substances exist Preventi...

Страница 5: ...put a battery in fire or water or heat it It may burst 3 Do not mix alkaline and manganese batteries It may cause liquid leakage or explosion 4 Set batteries correctly as shown by the polarity marks and Incorrect installation may cause liquid leakage or explosion 5 Remove batteries when the equipment is left unused for a long time about 1 month or longer Otherwise they may leak and cause the insid...

Страница 6: ...tored for a long time within a humid environment 2 Sudden temperature changes even under low humidity splashing cold water on the device 3 Operating the device when exposed to direct cold air from a refrigerator or steam Storage and Disposal Storage 1 Do not store the equipment in the place with high temperature humidity or receiving direct sunlight for a long period of time It should also be note...

Страница 7: ...Hz is displayed instead of the fat percentage From this number you can figure out the approximate fat ratio You can also refer to the Fish A Fish B and Fish C scale to create an original formula 5 Detecting previously defrosted products After freezing and thawing a fish cell membranes of the fish are destroyed This means that there is no difference in the flow of electricity within the fish Knowin...

Страница 8: ...1 4 Product package What included in the box Main device Accessories Attachment Batteries CCC size x 2 Manual 1 5 Main device interface details 7 ...

Страница 9: ...y tissue for battery contacts Wipe off any moisture If any battery erosion or leaks are found contact the distributor or place of purchase for detailed handling To make sure the battery cover is securely tight push the battery cover firmly from the bottom so that there is no gap Match the lines on the main unit as indicated below If the attachment is used use the same care as above Wipe off fish s...

Страница 10: ...Attachment Step Step Step Align the convex to the front and fit it straight up toward the body Installation is completed when the side hooks to the main body For removal put your finger in the space on the side hook and pull it down slightly 1 Use the attachment for small fish such as Horse mackerel Sardine Saury Grouper and Sea eel 2 For measuring in impedance mode or fish status freshness use an...

Страница 11: ...ode Not in contact It means that the contacts of the sensor electrode are not sufficient Keys Measurement Use this button to measure the fish Press to return to the previous display under setting or measurement mode ON OFF Turn on the device Return to the normal screen when setting or measurement mode Long press for powering down off the device Set Press to display the past measurement results Lon...

Страница 12: ...deline Center the sensor electrode on the center of the dorsal fin just above the sideline No 5 Saury Use attachment No 6 Yellowtail Center the sensor electrodes on the center of the belly fin just above the sideline Center the sensor electrode between the first and second fins just above the sideline No 7 1 Bluefin tuna back No 7 2 Bluefin tuna belly Align the tip of the sensor electrode to the b...

Страница 13: ... sensor electrode on the center of the dorsal fin just above the sideline Center the sensor electrode on the center of the dorsal fin just above the sideline No 13 Spanish mackerel No 14 Butterfish Align the back of the sensor electrode to the tip of the second fin just above the sideline Center the sensor electrode on the tip of the dorsal fin just above the sideline No 15 Sea bass No 16 Sailfin ...

Страница 14: ... between the first and second fins just above the sideline No 19 Sea eel Use attachment No 20 Horse mackerel 2 Straightening the fish align the tip of the sensor electrode to the anal position just above the lateral line Center the sensor electrode between the first and second fins just above the sideline 13 ...

Страница 15: ...rehouse the fish may still be alive If you take measurements immediately after when the fish died you may get a lower fat percentage We recommend that you first store the fish in ice and wait at least one hour before making measurements Also if several days have passed since the death please take the measurement using the next day after catching mode In Fish AnalyzerTM PRO the status of the fish o...

Страница 16: ...es key Place your thumb on the measurement button and the remaining fingers grip the body If touching the fish is ok support the fish with your fingertips and place the device If you can t touch the fish use your arm as a stand for stability 3 Sensor electrode contact 4 Confirm on screen display and by the sensor electrodes position Lightly place the four sensor electrodes on to the fish Make sure...

Страница 17: ...on is enabled the average value is displayed at the bottom center of the screen displayed to one decimal place Fish Analyzer TM PRO it displays the status of the fish or the fish freshness in 5 levels grades 4 Long press on the key to turn off the device when finished 3 3 See results from past measurements How to find past measurement results Operation Screen 1 Press key from the home screen 2 Eac...

Страница 18: ...t clear is displayed Choosing Yes with a cursor by moving it with key then press key 3 Clearing results is started and when clear complete is displayed deletion of the past measurement results is completed Press key to return to the normal screen Remarks Please note that clearing results will erase all past measurement results and the number of measurements 17 ...

Страница 19: ...display B as the condition is similar to the one before the fish starts to tighten and if blood remains in the body of the fish it may display C When freshness starts to decrease the impedance from the lower frequency band drops significantly This is because the cell structure changes and the cell electrical characteristics deteriorates Moreover the water content of cells decreases and the intrace...

Страница 20: ...he species with check mark レ are only displayed 4 After confirming the selection press key to return to Menu screen Press key again to return to the home screen then setting is completed Confirm that only the selected species are displayed with key List of all fish species Impedance mode Bluefin tuna back Salmon Bonito 2 Horse mackerel 1 Bluefin tuna back Salmon Bonito 2 Horse mackerel 1 Bluefin t...

Страница 21: ...o turn off the display after 10 seconds of use set Auto off 2 at 10 seconds Operation Screen 1 Press key to power on the device From the home screen hold down key until Menu is displayed 2 Match a cursor to Operation setting and then press key 3 When the operation settings are displayed move the cursor to 2 Auto off 2 by pressing key twice and then press key 4 Set 10 seconds by pressing for decrea...

Страница 22: ... the bottom of the screen Press key or the power button to turn off the device 4 4 Limitations of Fish Fat measurements In order for this device to measure accurate fish fat percentage the fish needs to be fresh If the fish is not fresh the fish fat percentage displayed will not be accurate If the Fish status is displayed as grade D level the fish fat percentage will not display since the fish doe...

Страница 23: ...The measurement is carried out by applying small electric current to the fish The electrical characteristics of the cells change with decreasing freshness The water content of the cells decreases with time which makes the electricity easier to flow through in low frequency bands thus reducing impedance resistance In the status of fish fish freshness mode it s necessary to keep track of the impedan...

Страница 24: ...oint Enter 4 for 4 digits after the decimal point 4 Next enter the sign or In this case no need to change from press key 5 Finally enter a numerical value Press key to move the digit and enter 0 0865 6 Next match a cursor to section by pressing key and then press key Taking the same procedures enter 4 8 for section After entry the cursor locates on section press key 7 After returning to fish speci...

Страница 25: ...Defrosted or F is displayed what does it mean This means the fish has been previously frozen and it will not measure fish fat percentage It s been Defrosted Page 6 Q3 The fish I want to measure is not listed in the 20 fish species support As the fish has not been pre calibrated you can use the impedance mode to measure the fish Page 20 Q4 How many measurements can the device hold The device can st...

Страница 26: ... remaining battery indication Others E 3 Status E E 7 E 2 E 4 Error100 05 Keys Refer to 2 2 Display and keys 06 Functions Fat display Displays fish fat amount that a raw fish contains Status of fish display Displays freshness in 5 levels grading Display of defrosted Determine if it has been previously frozen and defrosted Impedance entry Make original algorithm custom calibration Auto off 1 Automa...

Страница 27: ...erature 10 to 40 Operating humidity 30 R H to 85 R H no condensation 11 Diagram measurement unit unit mm millimeters Standard With attachment YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Phone 81 78 918 6 Fax 81 78 918 5552 26 ...