A
B
C
D
E
F
G
H
I
J
1
2
3
4
5
6
7
●
Confirmation of AUTO STANDBY operation
Setting
1) Turn off the power switch located on the rear panel.
2) In order to shorten the time required for operation
check; connect a 10k
Ω
resistor at both ends of R72 on
the MAIN (2) P.C.B. (Fig. 2)
3) Connect the output signal from the signal generator to
the INPUT 2 / L/MONO terminal of the unit.
4) Set the signal generator for the sine wave of 100Hz,
8mV.
5) Turn on the power switch located on the rear panel.
Confirmation
1) Set the AUTO STANDBY switch to the LOW position.
2) Turn on the STANDBY/ON switch.
The display LED lights up (green) and its color changes
to red after 4 to 5 seconds.
3) Turn off the STANDBY/ON switch.
The display LED goes off.
4) Set the AUTO STANDBY switch to the HIGH position.
5) Turn on the STANDBY/ON switch.
The display LED lights up (green) and its color remains
unchanged even after time have elapsed.
6) Turn off the STANDBY/ON switch.
The display LED goes off.
After confirmation
1) Turn off the power switch.
2) Disconnect the 10k
Ω
resistor connected to both ends of
R72.
●オートスタンバイ動作確認
設定
1)リアパネルにある主電源スイッチをOFFにします。
2)動作確認時間を短縮するため、MAIN(2)P.C.B.にある
R72の両端に10 kΩの抵抗を取り付けます。(Fig. 2)
3)信号発生器の出力信号を本機の入力2/L/MONO端子に
接続します。
4)信号発生器を正弦波、100 Hz、8 mVに設定します。
5)リアパネルにある主電源スイッチをONにします。
確認
1)オートスタンバイ/感度スイッチを「低」に合わせます。
2)STANDBY/ONスイッチをONにします。
表示LEDが点灯(緑色)します。4〜5秒後、表示LEDが
赤色に変わります。
3)STANDBY/ONスイッチをOFFにします。
表示LEDが消灯します。
4)オートスタンバイ/感度スイッチを「高」に合わせます。
5)STANDBY/ONスイッチをONにします。
表示LEDが点灯(緑色)します。時間が経過しても表示
LEDの色は変化しません。
6)STANDBY/ONスイッチをOFFにします。
表示LEDが消灯します。
確認終了後
1)主電源を切ります。
2)R72両端に取り付けた10 kΩの抵抗を外します。
R 7 2
1 0 k
Ω
R72
10 k
Ω
Fig. 1
D 3 3
D 3 4
A
B
G N D
Fig. 2
MAIN (2) P.C.B.
MAIN (10) P.C.B.
DRIVER
PS AMP
PS AMP
PS
AMP
PS
AMP
PROTECTION
A
B