3 - 49
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Leave the battery unused for more
than 30 minutes before measuring
its open-circuit voltage.
NOTE:
YES
NO
Adjust the voltage to obtain the
standard charging amperage.
Adjust the charging voltage to
20 ~ 25 V.
Leave the battery unused for more than 30 minutes before measuring
its open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
Charger
Ammeter
Set the charging voltage to 16 ~
17 V. (If the charging voltage is
lower charging will be insufficient,
if it is higher, the battery will be
over-charged.)
NOTE:
Monitor the amperage for 3 ~ 5
minutes. Is the standard charg-
ing amperage exceeded?
YES
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”.
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check
the charging amperage after 5 hours. If there is any charge in the
amperage, readjust the voltage to obtain the standard charging
amperage.
NO