5-15
POWR
Power unit
Reed valve check
1.
Check the reed valves. Replace if
cracked or damaged.
2.
Measure the valve warpage
a
. Replace
if out of specification.
3.
Measure the valve stopper height
b
.
Replace if out of specification.
Valve warpage limit: 0.2 mm (0.01 in)
Valve stopper height:
8.8–9.2 mm (0.35–0.36 in)