8-16
–
+
ELEC
4. Measure:
•
Armature coil resistance
(insulation/continuity)
Defect(s)
→
Replace the starter motor.
Inspecting steps:
•
Connect the pocket tester for the continuity
check
1
and the insulation check
2
.
•
Measure the armature coil resistances.
Armature coil resistance:
Continuity check:
0.014 ~ 0.018
Ω
at 20
°
C (68
°
F)
Insulation check:
More than 100 k
Ω
at 20
°
C (68
°
F)
•
If the resistance is incorrect, replace the starter
motor.
ELECTRICAL STARTING SYSTEM
SEA8300
5. Measure:
•
Brush length
a
Out of specification
→
Replace the starter
motor.
Brush length wear limit:
8.5 mm (0.33 in)
6. Measure:
•
Brush spring pressure
Fatigue/out of specification
→
Replace as a
set.
Brush spring pressure:
6.38 ~ 9.32 N
(650 ~ 950 g, 22.9 ~ 33.5 oz)
SEA8310
Содержание VX600ERG
Страница 1: ...VX600ERG SX600G MM600G VT600G SERVICE MANUAL LIT 12618 02 20 8EA 28197 10 981059 ...
Страница 57: ...2 43 INSP ADJ CARBURETORTUNING Guide for carburetion SEA2720 ...
Страница 79: ...2 65 INSP ADJ REAR SUSPENSION ...
Страница 220: ...8 21 ELEC CHARGING SYSTEM ...
Страница 236: ...8 37 ELEC SIGNAL SYSTEM ...
Страница 266: ...9 20 SPEC GENERAL TORQUE SPECIFICATIONS DEFINITION OF UNITS ...
Страница 267: ...SPEC 9 21 CABLE ROUTING SEA9010 ...
Страница 269: ...SPEC 9 23 CABLE ROUTING SEA9010 ...
Страница 271: ...SPEC 9 25 CABLE ROUTING SEA9020 ...
Страница 272: ...9 26 SPEC CABLE ROUTING 1 Brake hose 2 Oil pump cable 3 Throttle cable 4 Wire harness 5 Starter cable ...
Страница 273: ...SPEC 9 27 CABLE ROUTING SEA9030 ...
Страница 275: ...SPEC 9 29 CABLE ROUTING SEA9030 ...
Страница 277: ...SPEC 9 31 CABLE ROUTING SEA9040 ...
Страница 279: ...SPEC 9 33 CABLE ROUTING SEA9050 ...
Страница 281: ...SPEC 9 35 CABLE ROUTING SEA9050 ...
Страница 283: ...SPEC 9 37 CABLE ROUTING SEA9060 ...
Страница 287: ...Printed in USA E CR PRINTED ON RECYCLED PAPER ...