SETTING
7-2
That is:
• Higher temperature expands the air with its
resultant reduced density.
• Higher humidity reduces the amount of oxy-
gen in the air by so much of the water vapor
in the same air.
• Lower atmospheric pressure (at a high alti-
tude) reduces the density of the air.
EC714000
Effects of setting parts in relation to throt-
tle valve opening
1
Throttle valve opening
2
Full-open
3
Full-closed
EC71E003
Basic process of carburetor setting
Ex-factory setting is on the richer side, which
should basically have no problems with the
brake-in procedure.
Refer to “STARTING AND BREAK-IN” section
in the CHAPTER 1.
1. Adjustment of main jet
Use a main jet
1
with a smaller calibration
number if the engine does not develop
more than 12,000 rpm after a few laps of
the circuit when the water temperature
becomes stable [55°C (131°F) or more].
Example:#560
≥
#540
TUN