background image

SWP2 Owner’s Manual

2

Explanation of Graphical Symbols
Explication des symboles

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous 
voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

L’éclair avec une flèche à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’une « tension 
dangereuse » non isolée à l’intérieur de l’appareil, pouvant être suffisamment élevée pour constituer un risque d’électrocution.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the product.

Le point d’exclamation à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’instructions 
importantes sur l’emploi ou la maintenance (réparation) de l’appareil dans la documentation fournie.

IMPORTANT SAFETY INSTRUCTIONS

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in accordance with the 
manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, heat registers, 
stoves, or other apparatus (including amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or grounding-type 
plug. A polarized plug has two blades with one wider than the other. 
A grounding type plug has two blades and a third grounding prong. 
The wide blade or the third prong are provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.

10 Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit from 
the apparatus.

11 Only use attachments/accessories specified by the manufacturer.

12 Use only with the cart, stand, tripod, bracket, or table 

specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid 
injury from tip-over.

13 Unplug this apparatus during lightning storms or 

when unused for long periods of time.

14 Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way, such as 
power-supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been 
dropped.

PRÉCAUTIONS CONCERNANT LA 
SÉCURITÉ

1 Lire ces instructions.
2

Conserver ces instructions.

3

Tenir compte de tous les avertissements.

4

Suivre toutes les instructions.

5

Ne pas utiliser ce produit à proximité d’eau.

6

Nettoyer uniquement avec un chiffon propre et sec.

7

Ne pas bloquer les orifices de ventilation. Installer l’appareil 
conformément aux instructions du fabricant.

8

Ne pas installer l’appareil à proximité d’une source de chaleur comme 
un radiateur, une bouche de chaleur, un poêle ou tout autre appareil 
(y compris un amplificateur) produisant de la chaleur.

9

Ne pas modifier le système de sécurité de la fiche polarisée ou de la 
fiche de terre. Une fiche polarisée dispose de deux broches dont une 
est plus large que l’autre. Une fiche de terre dispose de deux broches 
et d’une troisième pour le raccordement à la terre. Cette broche plus 
large ou cette troisième broche est destinée à assurer la sécurité de 
l’utilisateur. Si la fiche équipant l’appareil n’est pas compatible avec 
les prises de courant disponibles, faire remplacer les prises par un 
électricien.

10 Acheminer les cordons d’alimentation de sorte qu’ils ne soient pas 

piétinés ni coincés, en faisant tout spécialement attention aux fiches, 
prises de courant et au point de sortie de l’appareil.

11 Utiliser exclusivement les fixations et accessoires spécifiés par le 

fabricant.

12 Utiliser exclusivement le chariot, le stand, le trépied, 

le support ou la table recommandés par le fabricant 
ou vendus avec cet appareil. Si l’appareil est posé 
sur un chariot, déplacer le chariot avec précaution 
pour éviter tout risque de chute et de blessure.

13 Débrancher l’appareil en cas d’orage ou lorsqu’il 

doit rester hors service pendant une période 
prolongée.

14 Confier toute réparation à un personnel qualifié. Faire réparer 

l’appareil s’il a subi tout dommage, par exemple si la fiche ou le 
cordon d’alimentation est endommagé, si du liquide a coulé ou des 
objets sont tombés à l’intérieur de l’appareil, si l’appareil a été exposé 
à la pluie ou à de l’humidité, si l’appareil ne fonctionne pas 
normalement ou est tombé.

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

ATTENTION : 

POUR RÉDUIRE LES RISQUES D'ÉLECTROCUTION, NE PAS RETIRER 

LE CAPOT (OU LE DOS). NE CONTIENT PAS DE PIÈCES NÉCESSITANT 

L'INTERVENTION DE L'UTILISATEUR. POUR TOUTE INTERVENTION, 

FAIRE APPEL À DES PROFESSIONNELS QUALIFIÉS.

ATTENTION

RISQUE DE CHOC 

ELECTRIQUE-NE PAS OUVRIR

The above warning is located on the top of the unit.

L’avertissement ci-dessus est situé sur le dessus de l’unité.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 
EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

AVERTISSEMENT

POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE 
ÉLECTRIQUE, N’EXPOSEZ PAS CET APPAREIL À LA PLUIE OU À 
L’HUMIDITÉ.

Содержание SWP2

Страница 1: ...Português Italiano Русский 日本語 Owner s Manual Bedienungsanleitung Mode d emploi Manual de instrucciones Manual do Proprietário Manuale di istruzioni Руководство пользователя 取扱説明書 JA RU IT PT ES FR DE EN L2 SWITCH SWP2 10MMF SWP2 10SMF ...

Страница 2: ...ture does not operate normally or has been dropped PRÉCAUTIONS CONCERNANT LA SÉCURITÉ 1 Lire ces instructions 2 Conserver ces instructions 3 Tenir compte de tous les avertissements 4 Suivre toutes les instructions 5 Ne pas utiliser ce produit à proximité d eau 6 Nettoyer uniquement avec un chiffon propre et sec 7 Ne pas bloquer les orifices de ventilation Installer l appareil conformément aux inst...

Страница 3: ...t occur in all installations If this product is found to be the source of inter ference which can be determined by turning the product OFF and ON please try to eliminate the problem by using one of the following measures Relocate either the product generating the interference or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker...

Страница 4: ...ssible If some trouble or malfunction occurs immediately disconnect the all plugs from the outlet Remove the electric plug from the outlet when the product is not to be used for extended periods of time Do not touch the product or the electric plug during an electrical storm Be sure to connect to an appropriate outlet with a protective grounding connection Improper grounding can result in electric...

Страница 5: ...ring the day in order to prevent the possibility of panel disfiguration unstable operation or damage to the internal components Condensation can occur in the product due to rapid drastic changes in ambient temperature when the product is moved from one location to another or air conditioning is turned on or off for example Using the product while condensation is present can cause damage If there i...

Страница 6: ...tion for users on collection and disposal of old equipment This symbol on the products packaging and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling of old products please take them to applicable collection points in accordance with your national legislation By disposing of the...

Страница 7: ... any other party handling or distributing the Software make no warranty neither explicit nor implicit regarding the merchantability or suitability of the Software for any particular purpose 2 Yamaha its subsidiaries their sales representatives and dealers and any other party handling or distributing the Software shall bear no responsibility for any damages including but not limited to lost profit ...

Страница 8: ...STATUS setting 14 VLAN setting 14 OFF setting 14 Initializing the SWP2 14 Using the Web GUI to restore the factory settings 14 Using the cold start command to restore the factory settings 15 Entering the I uppercase I key during startup to restore the factory settings 15 VLAN Use Cases 16 Redundant Dante connections 16 Separating control signals from audio signals 16 Specifications 17 ...

Страница 9: ...ommended settings such as QoS EEE and IGMP Snooping for stable operation of the Dante network can be specified with only DIP switch The 10GBASE SR LR ports support 10 gigabit allowing operation without fear of insufficient bandwidth even on a Dante network that is set to a sampling frequency of 96 kHz VLAN presets provided Three types of preset VLAN settings are provided allowing a more stable net...

Страница 10: ...nk aggregation is a function that bundles multiple LAN SFP ports that connect network devices and treats them as a single logical interface in order to expand the communication bandwidth A group that is bundled using link aggregation is called a link aggregation group LAG Link aggregation is a technology that is useful when multiple communications are occurring The communications can be distribute...

Страница 11: ...because of the optical fiber cables that are used and the conditions of installation Link up is possible only for 10GBASE SR LR between the same standards 10GBASE SR LR can not link up with 1000BASE optical standards Cleaning Correct communication might not be possible if debris and or dust has adhered to the ends of optical fiber cables or the ports Clean the equipment regularly by using commerci...

Страница 12: ...oad technical reference material HTML 1 In the VLAN presets the IGMP Snooping function is turned on except for VLAN 2 in presets A and B preventing multicast communication such as Dante s multicast flow from being forwarded to unnecessary routes For this reason in the case of A or B you should use the VLAN 1 port for audio signals such as Dante and use the VLAN 2 port for control signals 2 If you ...

Страница 13: ...32 type jack for supplying an external power supply 24V as a backup for the SWP2 s internal power supply Connect a Yamaha PA 700 AC adaptor or an equivalent product recommended by Yamaha CAUTION Before connecting the external power supply you must turn off the external power supply Failing to do so may cause electrocution or malfunctions EXT DC INPUT connector is intended to be supplied by Power S...

Страница 14: ... the factory settings NOTICE When restoring the factory settings note the following points All communication is halted immediately after execution When you execute this the settings will also return to their factory set state If necessary use external memory to save the settings before you proceed with initialization For details on how to export settings to external memory refer to the SWP2 series...

Страница 15: ...on a startup message does not appear 3 Press the Enter key The system waits for a user name to be entered If a user name has already been specified enter the user name When the unit is shipped from the factory a user name has not been specified so it need not be entered 4 Press the Enter key The system waits for a password to be entered If a password has already been specified enter the password W...

Страница 16: ...as for Editor or StageMix from Dante s audio signals making the network more stable This diagram shows a setup using VLAN preset B If VLANs are not used and control signals and audio signals flow across the same network the two will compete for communication bandwidth In order to prevent such an effect we recommend that you use VLANs to separate the control signal and audio signal networks P S P S...

Страница 17: ...P switches CONFIG VLAN PRESET Indicators Front POWER LED MODE 4 PORT 10 2 1 SFP 2 2 Operating temperature range 0 to 40 C Storage temperature range 20 to 60 C Power supply AC IN inlet AC100V 240V 50 60 Hz Internal power supply no power switch Power supply inlet locking type Power supply EXT DC INPUT inlet 24VDC 2V 0 78A XLR 4 32 type Connector Maximum power consumption Wattage Current 21W 0 35A He...

Страница 18: ...10 km 3 10GBASE SR SWP2 10MMF 10GBASE LR SWP2 10SMF 4 For the pin assignments refer to CONNECTOR PIN ASSIGNMENTS 5 Pin 4 24VDC pin 1 GND pins 2 and 3 N C External power supply requirements 24VDC 2V 0 78A CONNECTOR PIN ASSIGNMENTS CONSOLE RS 232C These signals are not used on the SWP2 Terminal Format Level Connector 1 10 1 IEEE802 3 10BASE T 100BASE TX 1000BASE T etherCON CAT5e 11 12 2 IEEE802 3ae ...

Страница 19: ...nual 19 Dimensions The contents of this manual apply to the specifications as of the firmware Rev 2 03 01 To obtain the latest manual access the Yamaha website then download the manual file 480 362 355 430 44 Unit mm ...

Страница 20: ......

Страница 21: ...6168 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia JA Wettergrensgata 1 400 43 Göteborg Sweden Tel 46 31 89 34 00 DENMARK Yamaha Music Denmark Fillial of Yamaha Music Europe GmbH Tyskland Generatorvej 8C ST TH 2860 Søborg Denmark Tel 45 44 92 49 00 NORWAY Yamaha Music Europe GmbH Germany Norwegian Branch Grini Næringspark 1 1332 Østerås Norway Tel 47 6716 7800 CYPRUS Y...

Страница 22: ...Published 03 2019 MWES A0 2019 Yamaha Corporation Manual Development Group VAV9140 Yamaha Downloads http download yamaha com Yamaha Pro Audio global website http www yamahaproaudio com ...

Отзывы: