ELEC
STARTER MOTOR
7-20
2. Measure:
9
commutator diameter
a
Out of specification
→
Replace the starter
motor.
3. Measure:
9
mica undercut
a
Out of specification
→
Scrape the mica to
the proper measurement with a hacksaw
blade that has been grounded to fit the
commutator.
NOTE:
The mica of the commutator must be undercut
to ensure proper operation of the commutator.
4. Measure:
9
armature assembly resistances (commuta-
tor and insulation)
Out of specification
→
Replace the starter
motor.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Measure the armature assembly resis-
tances with the pocket tester.
b. If any resistance is out of specification,
replace the starter motor.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Commutator wear limit
16.6 mm (0.65 in)
Mica undercut
1.35 mm (0.05 in)
Pocket tester
90890-03112
Armature coil
Commutator resistance
1
1
0.018–0.022
Ω
at 20°C (68°F)
Insulation resistance
2
2
Above 1 M
Ω
at 20°C (68°F)