50
RM1x
SOUND CONTROLLER 6 adjusts the envelope decay time specified by the Voice. This is a relative
parameter, and specifies an increase or decrease centered at 64.
BRIGHTNESS adjusts the cutoff frequency specified by the Voice. This is a relative parameter, and
specifies an increase or decrease centered at 64. Decreasing the value will make the sound more
mellow. For some voices, the effective range may be less than the range of the setting.
SOUND CONTROLLER 7 adjusts the LFO Frequency specified by the Voice. This is a relative
parameter, and specifies an increase or decrease centered at 64.
(3-2) CHANNEL MODE MESSAGES
STATUS
1011nnnn(BnH)
n = 0 ~ 15 VOICE CHANNEL NUMBER
CONTROL NUMBER
0ccccccc
c = CONTROL NUMBER
CONTROL VALUE
0vvvvvvv
v = DATA VALUE
(3-2-1) ALL SOUND OFF
(CONTROL NUMBER = 78H , DATA VALUE = 0)
Turns off the sound of all currently sounding notes on the corresponding channel. The status of
channel messages such as Note On and Hold On is also turned off.
(3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets the values of the following controllers.
PITCH BEND CHANGE
0 (center)
MODULATION
0 (of f)
AC1 CONTROLLER
0 (minimum)
EXPRESSION
127 (maximum)
SUSTAIN SWITCH
0 (of f)
PORTAMENTO SWITCH
0 (of f)
SOSTENUTO SWITCH
0 (of f)
SOFT PEDAL
0 (of f)
NRPN
Un-set status. Internal data will not change.
RPN
Un-set status. Internal data will not change.
PORTAMENT CONTROL
reset
The following data will not change.
PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN, HARMONIC CONTENT,
RELEASE TIME, ATTACK TIME, BRIGHTNESS, SOUND CONTROLLER 6,SOUND
CONTROLLER 7, DRY SEND LEVEL,EFFECT SEND LEVEL 1, EFFECT SEND LEVEL 3,EFFECT
SEND LEVEL 4,PITCH BEND SENSITIBITY, FINE TUNING, COURSE TUNING
(3-2-3) ALL NOTE OFF (CONTROL NUMBER = 7BH , DATA VALUE = 0)
Turns off all notes of the corresponding channel which are on. However if Sustain or Sostenuto are on,
the sound will continue until these are turned off.
(3-2-4) OMNI MODE OFF (CONTROL NUMBER = 7CH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Sets the VOICE RECEIVE
CHANNEL to OMNI OFF and CHANNEL = 1.
(3-2-5) OMNI MODE ON (CONTROL NUMBER = 7DH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Does not set OMNI ON. Sets the
VOICE RECEIVE CHANNEL to OMNI ON.
(3-2-6) MONO (CONTROL NUMBER = 7EH , DATA VALUE = 0)
Performs the same processing as when All SOUND OFF is received, and if the 3rd byte (mono
number) is in the range 0 - 16, sets the corresponding channel to Mode 4 (m=1). If in the VOICE
MODE, Mode 2 (m=1) is also possible, according to the VOICE RECEIVE CHANNEL.
(3-2-7) POLY (CONTROL NUMBER = 7FH , DATA VALUE = 0)
Performs the same processing as when ALL SOUND OFF is received, and sets the corresponding
channel to Mode 3. When in the VOICE MODE, Mode 1 is also possible, according to the VOICE
RECEIVE CHANNEL.
(3-3) REGISTERED PARAMETER NUMBER
STATUS
1011nnnn(BnH)
n = 0 - 15 VOICE CHANNEL NUMBER
LSB
01100100(64H)
RPN LSB
0ppppppp
p = RPN LSB (Refer to the table on the following page.)
MSB
01100101(65H)
RPN MSB
0qqqqqqq
q = RPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
m = Data Value
DATA ENTRY LSB
00100110(26H)
DATA VALUE
0lllllll
l = Data Value
First transmit an RPN MSB and RPN LSB to specify the parameter that is to be controlled, then use
Data Entry to set the value of the specified parameter.
RPN
D.ENTRY
LSB MSB
MSB LSB
PARAMETER NAME
DATA RANGE
00H 00H
mmH ---
PITCH BEND SENSITIVITY
00H - 18H (0 - 24 semitones)
01H 00H
mmH llH
MASTER FINE TUNE
{mmH,llH} = {00H,00H} - {40H,00H} - {7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
02H 00H
mmH ---
MASTER COARSE TUNE
28H - 40H - 58H (-24 - 0 - +24 semitones)
7FH 7FH
--- ---
RPN RESET
Set to a condition in which the RPN number is unspecified.
Internal settings will not change.
(3-4) NON-REGISTERED PARAMETER NUMBER
STATUS
1011nnnn(BnH)
n = 0 - 15 VOICE CHANNEL NUMBER
LSB
01100010(62H)
RPN LSB
0ppppppp
p = NRPN LSB (Refer to the table on the following page.)
MSB
01100011(63H)
RPN MSB
0qqqqqqq
q = NRPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB 00000110(06H)
DATA VALUE
0mmmmmmm
m = Data Value
First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be controlled, then
use Data Entry to set the value of the specified parameter.
NRPN
D.ENTRY
MSB LSB
MSB LSB
PARAMETER NAME
DATA RANGE
01H 08H
mmH ---
VIBRATO RATE
00H - 40H - 7FH (-64 - 0 - +63)
01H 09H
mmH ---
VIBRATO DEPTH
00H - 40H - 7FH (-64 - 0 - +63)
01H 0AH
mmH ---
VIBRATO DELAY
00H - 40H - 7FH (-64 - 0 - +63)
01H 20H
mmH ---
FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)
01H 21H
mmH ---
FILTER RESONANCE
00H - 40H - 7FH (-64 - 0 - +63)
01H 63H
mmH ---
EG ATTACK TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 64H
mmH ---
EG DECAY TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 66H
mmH ---
EG RELEASE TIME
00H - 40H - 7FH (-64 - 0 - +63)
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS
11111110
(FEH)
Transmitted at intervals of approximately 200 msec.
Not transmitted during disk read/write operations.
Once this message is received, SENSING will begin. If neither STATUS nor DATA messages are
received for an interval longer than approximately 350 msec, the MIDI RECEIVE BUFFER will be
cleared, and all sounding notes and SUSTAIN SWITCH will be forced off. Also, data for each of the
controls will be reset to specific values.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1)UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1)GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The following controller values will be reset.
VOLUME
100
PAN
Center
PROGRAM CHANGE
1 (Grandpno)
BANK SELECT MSB
0
REVERB DEPTH
4
PITCH BEND CHANGE
0 (center)
MODULATION
0 (off)
EXPRESSION
127 (maximum)
SUSTAIN SWITCH
0 (off)
SOSTENUTO SWITCH
0 (off)
RPN
Un-set status.
PORTAMENT CONTROL
reset
MIDI MASTER VOLUME
127 (maximum)
PITCH BEND SENSITIBITY
02 (2 semitones)
FINE TUNING
0
COURSE TUNING
0
(3-6-1-2)IDENTITY REQUEST (Received only)
F0H 7EH 0nH 06H 01H F7H ("n" is the device number, but the RM1x receives this in
Omni.)
(3-6-1-3)IDENTITY REPLY (Transmitted only)
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 01H F7H
dd;Device Number Code
RM1x = 1DH,03H
(3-6-2)UNIVERSAL REALTIME MESSAGE
(3-6-2-1) MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
Modifies the MASTER VOLUME value.
The value of mm is used as the MIDI Master Volume (the ll value is ignored).
(3-6-3)PARAMETER CHANGE
(3-6-3-1) MIDI MASTER TUNING
F0H 43H 1nH 27H 30H 00H 00H mmH llH ccH F7H
Modifies the MASTER TUNE value.
The values of mm and ll are used as the MIDI Master Tuning.(n and cc values are
ignored.)
T = M*200/256-100
Where
T : actual tuning value (-99 - +99)
M: a one-byte value with MSB of "mm" bits 0-3, and LSB of
"ll" bits 0-3.
(3-6-3-2) XG SYSTEM ON
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
device Number
01001100
4C
Model ID
0aaaaaaa
00
Address High
0aaaaaaa
00
Address Mid
0aaaaaaa
7E
Address Low
00000000
00
Data
11110111
F7
End of Exclusive
When ON is received, controllers will be reset and all Multi Part and Effect data of the
attached table will be reset to the XG default values.
(3-6-3-3) XG PARMETER CHANGE
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0001nnnn
1n
device Number
01001100
4C
Model ID
0aaaaaaa
aaaaaaa
Address High
0aaaaaaa
aaaaaaa
Address Mid
0aaaaaaa
aaaaaaa
Address Low
0ddddddd
ddddddd
Data
|
|
11110111
F7
End of Exclusive
For parameters with a Data Size of 2 or 4, the corresponding amount of data will be
transmitted.
For Addresses and Byte Counts, refer to the attached tables.
The following 3 types are received.
System Data
Multi Effect Data
Multi Part Data