45
En
Optimizing the speaker settings automatically (YPAO)
English
AD
V
A
NCED
OP
ERA
TI
ON
Warning messages
If a warning message is displayed after the measurement, you can still save the measurement results.
However, we recommend you perform YPAO again in order to use this unit with the optimal speaker settings.
Note
• If more than one warning is detected, use the cursor keys (
B
/
C
) to check another warning message.
• To return to the previous state after checking the warning message, press the cursor key (
D
)).
Warning message
Cause
Remedy
W-1 Out of Phase
A speaker cable may be connected with the
reverse polarity (+/-).
check the cable connections (+/–) of the
speakers.
If the speaker is connected incorrectly, turn off
this unit and then reconnect the speaker cable.
Depending on the type of speakers or room
environment, this message may appear even if
the speakers are connected correctly. In this
case, you can ignore the message.
W-2 Over Distance
A speaker is placed more than 24 m (80 ft) from
the listening position
Move the speaker within 24m (80 ft) of the
listening position.
W-3 Level Error
There are significant volume differences
between the speakers.
Check the usage environment and cable
connections (+/–) of each speaker, and the
volume of the subwoofer. We recommend using
the same speakers or speakers with
specifications that are as similar as possible.
Out of Phase
YPAO W-1