background image

Special considerations

21

KEY IN CUE button (GATE PRM screen)

Operation will change as follows, depending on the 
online/offline state of PM1D Manager and on the 
presence or absence of a console.

(*) In order to avoid inconsistencies due to the fact that 

the selected channel is not linked between the PC and 
console, this will never be displayed on the PC.

SYSTEM CONFIGURATION in screens such as 
the SYS/W.CLOCK function SYSTEM CON-
NECTION screen and ENGINE SELECT

Operation will change as follows, depending on the 
online/offline state of PM1D Manager and on the 
presence or absence of a console.

For reasons of safety, the above settings will not be 
reflected in the connected device even if you select 
UPLOAD when initiating the connection. (Conversely, 
the setting of the connected device will be reflected on 
the PC.)

UNIQUE No. in the SYS/W.CLOCK function 
SYSTEM CONNECTION screen

Operation will change as follows, depending on the 
online/offline state of PM1D Manager and on the 
presence or absence of a console.

DIGITAL I/O connector select button and PC 
CONNECTION area in the SYS/W.CLOCK 
function SYSTEM CONNECTION screen

These functions are specific to the console, and do 
not exist in PM1D Manager.

MUTE MODE buttons in the lower part of the 
display / DIRECT RECALL screen / MUTE 
GROUP ASSIGN screen

These are not linked with the console in the system, 
and can therefore be operated independently.

LOAD/SAVE screen

The number of characters that can be used in a file-
name is eight characters plus the filename extension 
(.PM1). If this number of characters is exceeded, the 
file cannot be recognized by PM1D Manager, and the 
file may not be displayed in the file list. Please be 
aware of this if you modify the filename in Windows.

Simultaneous use with other serial communi-
cation software such as PM1D LOAD

PM1D Manager cannot be used simultaneously on 
the same port as other serial communication soft-
ware such as PM1D LOAD.

Please exit all such software before starting PM1D 
Manager.

PC connections in a system that includes a 
console

If the system includes a console, connections with 
the PC are limited in the following ways.

When online, the following items cannot be operated 
from PM1D Manager. (However, they can be oper-
ated from the console.)

– Load/save operations in the LOAD/SAVE screen 

(UTILITY function)

– STORE, TITLE EDIT, and APPLY EDIT button 

operations, changes to Scene Link, and Scene 
Sort in the MEMORY screen (SCENE function)

– STORE, TITLE EDIT, and APPLY EDIT button 

operations in the various libraries

– Startup/viewing/operations in the UNIT, 

PATCH, and NAME library popup windows

Offline

Operable

Online

Console exists in 
the system

Not displayed. (*)

Console does not 
exist in the system

Operable

Offline

Operable

Online

Not operable

Offline

Not displayed

Online

Console exists in 
the system

Displayed / not setta-
ble

Console does not 
exist in the system

Displayed / settable

Содержание PM1D Manager V2

Страница 1: ...d Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and other countries Pentium II is a registered trademark of Intel Corporation Compact Flash is a trademark...

Страница 2: ...display common to all screens 7 Lower part of the display common to all screens 7 Lower part of the function menu 8 Option popup window 8 REMOTE CONTROL SETUP popup window 9 Communication between PM1...

Страница 3: ...rols of the console and the knobs buttons of the software The names of controls on the console switches encoders are enclosed in square brackets in order to distinguish them from the knobs and buttons...

Страница 4: ...em you may be asked to restart the system during the installation process If so installation will continue automatically after you restart 3 As directed by the instructions on the screen click the Nex...

Страница 5: ...ther of the following methods to start up PM1D Manager 1 From the Windows Start menu select Start Programs YAMAHA PM1D System PM1D Manager 2 Double click the PM1D Manager icon that was cre ated during...

Страница 6: ...k either the Initialize All Memories button or the Initialize Current Memories button If you click the Initialize All Memories button The current settings of the PM1D Manager as well as the scene memo...

Страница 7: ...ication Setup Lower part of the display common to all screens 1 RECALL button MUTE button Select the function of the DIRECT RECALL MUTE MASTER 1 12 buttons 2 from the following two choices DIRECT RECA...

Страница 8: ...func tion menu screen or choose Manager from the Option menu of the menu bar 1 Communication Setup Communication Port From the pulldown menu select the port that will be used for communication Only C...

Страница 9: ...r has been established 4 CH ASSIGN Here you can assign the correspondence between input channels of the remote controller and input channels of the PM1D in units of two channels If you don t want to m...

Страница 10: ...ed and terminated System connection examples Example 1 Standard mode connect the PC to the console Console 1 Engine 1 Example 2 Standard mode connect the PC to the engine Example 3 Mirror mode connect...

Страница 11: ...off the console engine or connect disconnect cables If you perform these actions before exiting communication may become impossible until you restart your PC USB connection is not guaranteed to be fa...

Страница 12: ...nd slave are handled separately so this is considered as two systems 6 In the Function menu screen click the ONLINE OFFLINE button The following popup window will appear In this popup window you can s...

Страница 13: ...to the engine system example 4 on p 10 When a console is connected to a system that consisted of only an engine and a PC system example 5 on p 10 When the cable connection is accidentally broken or if...

Страница 14: ...1 3 Start up PM1D Manager and open the Option popup window either by clicking the OPTION but ton in the lower left of the function menu screen or by choosing Manager Option from the Option menu in the...

Страница 15: ...G Hi Mid Q Hi Mid Q Hi Mid F Hi Mid F Hi Mid G Hi Mid G Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF or LPF Hi F Hi Mid F Hi G Hi Mid G Hi LPF Ignored LPF On On On Input...

Страница 16: ...G Ignored HPF On SubLow On Ignored Low Q Low Mid Q Low F Low Mid F Low G Low Mid G Low On Ignored Low Mid Q Hi Mid Q Low Mid F Hi Mid F Low Mid G Hi Mid G Low Mid On Ignored Mid Q Mid F Mid G Mid On I...

Страница 17: ...id G Low Mid On Ignored Mid Q Ignored Mid F Ignored Mid G Ignored Mid On Ignored Hi Mid Q Hi Mid F Hi Mid G Hi Mid On Ignored Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF...

Страница 18: ...Hi LPF Ignored LPF On Hi On Ignored On On Stereo Comp Ignored Stereo Comp LocComp On On Ignored Link Type Type Attack Attack Release Release Ratio Ratio Gain Gain Knee Knee Threshold Threshold Input...

Страница 19: ...n 16 the data is fixed as space on the remote controller Mute Master 9 12 Output Mute Master Surround Mode Surround Mode Input CH Name Short Input CH Name Short column1 4 Input CH Name Long Input CH N...

Страница 20: ...recall occurs MIDI program changes control changes The MIDI ports of the PC cannot be used as MIDI inputs outputs for the PM1D Manager software TC events The setting can always be made but since oper...

Страница 21: ...e in the system and can therefore be operated independently LOAD SAVE screen The number of characters that can be used in a file name is eight characters plus the filename extension PM1 If this number...

Страница 22: ...n the Copy files from sec tion of the subsequent dialog box enter D USBdrv2k_ replacing D with the drive letter of your CD ROM drive and then click OK The driver is installed and the message Completin...

Страница 23: ...SB Driver fails the CS1D DSP1D may be registered as an unknown device and you may not be able to rein stall the driver until the unknown device is deleted In this case open the System control panel cl...

Страница 24: ...U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2002 Yamaha Corporation WF52700 806IPAPx x 0xA1 Printed in Japan...

Отзывы: