62
MONTAGE6/MONTAGE7
LCD display
Test items and judging conditions
12 : USB (to DEVICE)
Checks whether the USB TO DEVICE terminal work properly or not.
1)
Press the [ENTER] button first. “
Insert USB Memory! and Press [ENTER]
” is shown on the
LCD.
2)
Insert the USB flash drive.
3)
Press the [
ENTER
] button to start the test.
4)
Confirm that “
OK
” is shown on the LCD.
5)
When OK/NG of the test result is shown, testing is finished and the display is changed to the test
item selection screen.
6)
Disconnect the USB flash
drive.
13 : USB (to HOST)
Checks whether the USB TO HOST terminal work properly or not.
1) Press the [ENTER] button first. “
Connect USB! and Press [ENTER]
” is shown on the LCD.
2) Connect the USB TO DEVICE terminal and USB TO HOST terminal by using the USB cable.
3) Press the [ENTER] button to start the test.
4) Confirm that “
OK
” is shown on the LCD.
5)
When OK/NG of the test result is shown, testing is finished and the display is changed to the test
item selection screen.
6)
Disconnect the USB cable.
14 : OUTPUT-L (-12dB)
Checks each output level and pitch from the L channel of the jacks.
1)
Connect the frequency counter to the PHONES jack at L.
2)
Connect the level meter to an output jack.
3)
Set the [MASTER VOLUME] control to the maximum position.
4)
Press the [ENTER] button to produce the 1kHz sine wave sound. “
ON
” is shown on the LCD.
5)
Measure the frequency and confirm that the measured value is 1 kHz ± 0.2Hz.
6) Measure the output level and confirm that the measured values are within the specified range.
[PHONES]
(33
-ohms
load)
PHONES L: -6.5 dBu±2 dB
PHONES R: -60 dBu or less
[OUTPUT (Balanced)]
(600
-ohms
load)
OUTPUT L/MONO (HOT/COLD): +2.7 dBu±2 dB
OUTPUT R (HOT/COLD): -90 dBu or less
OUTPUT L/MONO (HOT/COLD): -1.7 dBu±2 dB
OUTPUT R (Unconnected)
[ASSIGNABLE OUTPUT (Balanced)]
(600
-ohms
load)
OUTPUT L (HOT/COLD): +2.7 dBu±2 dB
OUTPUT R (HOT/COLD): -90 dBu or less
Distortion rate
All output terminal L: 0.1 % or less
7) Set the [MASTER VOLUME] control to the minimum position.
8) Measure the output level and confirm that the measured values are within the specified range.
[OUTPUT (Balanced)]
(600
-ohms
load)
OUTPUT L/MONO (HOT/COLD): -73 dBu or less
9)
Press the [EXIT] button, and testing is finished and the display is changed to the test item selection
screen.
Содержание Montage 6
Страница 31: ...31 MONTAGE6 MONTAGE7 Component side to EMKS CN4 to AJK CN001 to DJK CN103 to PNL CN100 A A 2NA ZK72200...
Страница 32: ...MONTAGE6 MONTAGE7 32 DM Circuit Board 2NA ZK72200 B B...
Страница 33: ...33 MONTAGE6 MONTAGE7 Pattern side 2NA ZK72200 B B...
Страница 35: ...35 MONTAGE6 MONTAGE7 Scale 90 100 Pattern side 2NA ZM35120 AJK Circuit Board...
Страница 36: ...MONTAGE6 MONTAGE7 36 PNL Circuit Board to AJK CN003 to AJK CN004 to DJK CN100 C C 2NA ZP05150 2...
Страница 37: ...37 MONTAGE6 MONTAGE7 Scale 80 100 Component side N100 to PNR CN100 to DM CN504 C C 2NA ZP05150 2...
Страница 38: ...MONTAGE6 MONTAGE7 38 PNL Circuit Board 2NA ZP05150 2 D D...
Страница 39: ...39 MONTAGE6 MONTAGE7 Scale 80 100 2NA ZP05150 2 Pattern side D D...
Страница 40: ...MONTAGE6 MONTAGE7 40 PNR PNR EN Circuit Board 2NA ZP05160 to PNL CN103 E E...
Страница 41: ...41 MONTAGE6 MONTAGE7 Scale 90 100 2NA ZP05160 Component side to PNL CN103 E E...
Страница 45: ...45 MONTAGE6 MONTAGE7 H H H H J J J J Scale 90 100 MK61L Circuit Board MONTAGE6 Pattern side 2NAKZ WD80020 5...
Страница 47: ...47 MONTAGE6 MONTAGE7 Scale 90 100 MKH Circuit Board MONTAGE6 Pattern side 2NAKZ ZG72570 3 L L L L...
Страница 49: ...49 MONTAGE6 MONTAGE7 Scale 90 100 MK76L Circuit Board MONTAGE7 Pattern side 2NAKZ WD80730 1 Q Q Q Q R R R R...
Страница 51: ...51 MONTAGE6 MONTAGE7 Scale 90 100 MKH Circuit Board MONTAGE7 Pattern side 2NAKZ ZG72740 1 U U U U V V V V...
Страница 99: ...99 MONTAGE6 MONTAGE7 4 Searching for the updater OK 5 Finish Please turn off 6 USB 7 8 23...