GX-700/GX-700VCD
GX-700/VCD
Preset group
A
B
C
D
E
P1
P2
P3
P4
P5
P6
P7
P8
CAUTION : When executing Test program No. 2 RAM CLEAR, be sure to write down the preset memory contents of the
tuner, using a table like the one shown below. Execution of RAM CLEAR will set the memory contents of the
tuner back in the factory preset state which means that all the memories preset by the user will be erased.
●
MAKER’S PRESET
NOTE 1) PRESET PAGE
............................................ A : FM
B : AM
C : FM
D : AM E : FM
BAND
FM (MHz)
AM (kHz)
MARKETS
U, C, R, T
(100k/10k)
A, B, G, L, R, T (50k/9k)
U, C, R, T
(100k/10k)
A, B, G, L, R, T (50k/9k)
8
107.9
107.90
1440
1440
7
106.1
106.10
1350
1350
6
88.1
88.10
900
900
5
107.9
108.00
1710
1611
4
101.5
101.50
530
531
3
87.5
87.50
1400
1404
2
95.1
95.10
1080
1080
1
98.1
98.10
630
630
PRESET No.
16
Equalizer test mode (Test program No. 01)
When the equalizer test mode is set, “GEQ - xxx” is displayed. “xxx” represents the 3 band value of GEQ.
It is possible to set the GEQ value directly, using the buttons on the remote control unit.
Example : To obtain flat
GEQ -
6
6
6
Low tone
Intermediate tone
High tone
Displayed value
0
1
2
3
4
5
6
7
8
9
A
B
C
Gain (dB)
-12
-10
-8
-6
-4
-2
0
+2
+4
+6
+8
+10
+12
Operation Procedure
• To set a value for each band
[ 0 ] to [ 9 ], [ A(TIME) ], [ B(PROG) ], [ C(R.TIME)]
• To set all bands to Min (-12dB)
[ D(EDIT) ]
• To set all bands to Max (+12dB)
[ E(+10) ]
• To cancel this test mode, press the STANDBY/ON button. (The production mode will be restored.)
■
TAPE TEST MODE
When TAPE TEST MODE is set through SYSTEM TEST MODE, “Tape Test XXXX” appears on the FL display.
(XXXX is the counter value.)
The operation condition of the deck section will be as follows.
• When the reverse mode is set to “endless”, the number of playback repetition becomes unlimited.
(It is set to “8 “ times in the product mode.)
• When in the REC mode, AUX/MD is used automatically for the input source.
Fan test mode (Test program No. 13)
When the fan test mode is set, “Temp xx y” is displayed. “xx” represents the detected temperature of the Power
IC and “y” the value of the fan control level. It is possible to run the fan regardless of the detected temperature.
Operation Procedure
Pressing the
w
INPUT (up) or
q
INPUT (down) button causes the fan control level value to change. To cancel this
test mode, press the STANDBY/ON button. (The production mode will be restored.)