Maintenance
55
NOTICE
ECM01530
Do not perform this procedure while the
engine is running. The water pump may be
damaged and severe damage from over-
heating can result.
1.
After shutting off the engine, unscrew the
garden hose connector from the fitting on
the bottom cowling.
2.
Screw the garden hose adapter onto a
garden hose, which is connected to a
fresh water supply, and then connect it to
the garden hose connector.
3.
With the engine off, turn on the water tap
and let the water flush through the cool-
ing passages for about 15 minutes. Turn
off the water and disconnect the garden
hose adapter from the garden hose con-
nector.
4.
Reinstall the garden hose connector onto
the fitting on the bottom cowling. Tighten
the connector securely.
NOTICE:
Do not
leave the garden hose connector
loose on the bottom cowling fitting or
let the hose hang free during normal
operation. Water will leak out of the
connector instead of cooling the en-
gine, which can cause serious over-
heating. Be sure the connector is
tightened securely on the fitting after
flushing the engine.
[ECM00541]
TIP:
●
When flushing the engine with the boat in
the water, tilting up the outboard motor until
it is completely out of the water will achieve
better results.
●
For cooling system flushing instructions,
see page 52.
EMU28452
Cleaning the outboard motor
After use, wash the exterior of the outboard
motor with fresh water. Flush the cooling sys-
tem with fresh water.
1. Fitting
2. Garden hose connector
3. Garden hose adapter
U6DXK0E0.book Page 55 Friday, May 13, 2011 3:08 PM