5-
18
5
PA
RAMETERS
5-2 Parameter Description
PRM59: I/O assignment selection (Available with Ver. 13.57 or later)
This parameter selects the function to be assigned to each I/O signal.
This parameter setting allows changing the function assigned to each I/O signal. This
makes it possible to output the destination point number and perform jog movement.
After changing the I/O assignment, the ERCX controller must be restarted to enable the
changes.
For more details, see "3-7 I/O assignment change function".
Input range:
0 or another number (See the I/O assignment list)
Meaning:
PRM59 = x
x x x
↑ ↑ ↑
e w q
q
I/O assignment type selection
00
: Type 0 (Conventional type/standard)
20, 21 : Type 2 (Point number output type)
30, 31 : Type 3 (Point teaching type)
* Type 1 cannot be used with the ERCX controller.
w
Point output selection
Make setting only for type 2 (point number output type)
and type 3 (point teaching type).
0: Outputs when movement ends normally.
1: Outputs when movement command is received.
2: Point zone output
PO output occurs when the robot enters the point data
(registered at controller)
±
position judgment parameter
range.
3: Movement point zone output (supported in Ver. 13.64 and
later versions):
PO output occurs when the robot enters the
±
position
judgment parameter range for the point data registered at
the controller and which serves as the movement point data
for the point movement command (ABS-PT, INC-PT).
e
Point zone judgment method selection (supported in Ver. 13.64 and
later versions):
The position judgment parameter is selected when the point output
selection is "2" (point zone output) or "3" (movement point zone
output).
0: OUT valid position
1: Positioning-completed pulse
Default value: 0
c
CAUTION
Any value other than the above is handled as a "0" (type 0).
Example: If set to 2331, this is handled as a "0" (type 0).
If set to 10, this is handled as a "0" (type 0).
Moreover, if Type 2 (point signal output type) or Type 3 (point teaching type) is selected in ERCX versions prior
to Ver. 13.64, with the point output selection specified as "3", this is processed as a "0" (Type 0) setting.
Example: At ERCX version prior to Ver. 13.64:
If set to 331, this is handled as a "0" (type 0).
n
NOTE
In controller versions prior to Ver. 13.64, the "OUT valid position" is the only point zone judgment method.
Содержание ERCX Series
Страница 2: ......
Страница 8: ...vi MEMO ...
Страница 60: ...3 36 MEMO ...
Страница 90: ...5 20 MEMO ...
Страница 168: ...9 16 MEMO ...
Страница 232: ...12 10 MEMO ...
Страница 248: ...14 4 MEMO ...
Страница 249: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Страница 253: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Страница 259: ...MEMO ...