DVR-S100/NX-SW100
59
DVR-S100/NX-SW100
Display
Description
WAIT
Bus is being checked.
NoEr
No error detected.
DATA
Data bus shorted or open.
RSCS
/RAS or /CAS shorted, or open.
ADDR
Address bus shorted or open.
12. DSP RAM CHECK
This menu is used to self-diagnose whether or not the bus
connection for the YSS938 and the external RAM is made
properly.
During signal processing, the status before execution of
this menu is maintained.
The address bus and the data bus are checked and the
connection condition is displayed.
When no error is detected, "NoEr" appears on display.
YSS938 Bus Check
12. DSP RAM CHECK
YSS938と外付けRAMとのバス接続の正否を自己診断しま
す。
信号処理は、このメニューを実行する前の状態を維持しま
す。
アドレスバス、データバスのチェックを行い、接続正否を
表示します。
エラーが検出されなかった場合は、 NoEr と表示されま
す。
YSS938 BUS CHECK
PLD/SRAM BUS CHECK
Display
Description
WAIT
Bus is being checked.
NoEr
No error detected.
DATA
Data bus shorted or open. (XX: 00-07)
ADDR
Address bus shorted or open. (XX: 00-0E)
PLD/SRAM BUS CHECK
13. SOFT SW
This menu is used to confirm the function settings on
P.C.B..
MODEL SETTING
: DVX only
13. SOFT SW
P.C.B.上の機能設定を確認する機能です。
SW MODE
: Select PCB. Do not select SOFT.
SW MODE
:PCBを選択してください。SOFTには設定し
ないでください。
MODEL SETTING
:DVXのみ
MTT
: Mute Trigger
(Not used in this model)
Byte No.
Function
1
Mute condition
2
Factor of the last mute
3
Error count of YSS938-FSCNT
4
Mute count by YSS938-FSCNT
5
Error factor of down load of CS49329
MTT
: Mute Trigger
(使用しません)
Содержание DVR-S100