DPX-530
25
DPX-1200DPX-530
■
SERVICE COMMANDS
Display the operation status screen
Hold down the [
], [
], and [ENTER] buttons on the projector together to
display the picture shown on the right.
Press the [MENU] button to cancel this picture.
S/W VERSION
: The software’s version
SET TIME
: Projector operating time (Cumulative projector operating
time), impossible to reset.
LAMP TIME
: Lamp operating time, possible to reset.
LAMP RESET
: Number of times the lamp operating time has been reset,
impossible to reset.
V-FREQ
: Vertical frequency of the input signal
H-FREQ
: Horizontal frequency of the input signal
TEMP-ERR OR TIME : Time when a temperature error occurred.
0H0M is displayed when the power hasn’t been turned off
because of a temperature error.
(ERR MODE)
: The sensor that caused power-off is indicated within the
parentheses.
IN TEMP
(*1)
: Intake temperature (
°
C)
LAMP TEMP
(*1)
: Lamp temperature (
°
C)
*1)
The figures in the parentheses are the “temperature when the
power is turned off due to a temperature failure”. The default value 0
is shown in the parentheses when the warning record has been
reset. Table 1 shows the temperature setting for each sensor.
FAN MODE
: Rotation speed of the fan (0 to 25)
Reset to the factory settings
Use the procedure below to reset the setting values and the warning record to
the factory settings.
Press the [MENU], [ENTER], and [
] buttons on the projector at the same
time.
When the reset command is accepted, the STATUS LED will flash green two
times.
Note1:
It takes about 10 seconds for the projector to complete the process
of resetting to the factory settings because the iris is fully opened in
the process. Upon completion of the reset process, the STATUS
LED will flash green two times. Do not disconnect the AC cord while
the STATUS LED is flashing.
Note2: After the settings are reset, the menu language will be English.
Reset the lamp operating time
After replacing the lamp, reset the lamp operating time using the procedure
below.
Plug in the power cable and press the [STANDBY/ON], [
] and [
] buttons
on the projector at the same time.
When the reset command is accepted, the STATUS indicator will flash two times.
SENSOR
Warning
indication at
Forced
power-off at
Power-on
at
IN TEMP
51
°
C
52
°
C
47
°
C
LAMP TEMP
84
°
C
85
°
C
75
°
C
Table 1 TEMPERATURE SETTING FOR EACH SENSOR
Following are the reference of the life times of the consumable parts.
• Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max. 4,000 hours (When LAMP MODE is CINEMA.)
Max. 2,000 hours (When LAMP MODE is BRIGHT.)
• CW UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. 5,000 hours
• Cooling fan (power) . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (DMD) . . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (lamp) . . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (exhaust) . . . . . . . . . . . . . . . . . . . Approx. 5,000 hours
S/W VERSION
1.00DP53
SET TIME
519H 04M
LAMP TIME
519H 04M
LAMP RESET
1
V-FREQ
60 Hz
H-FREQ
48.4 kHz
TEMP ERROR TIME
1000H 20M
(ERROR MODE)
(INTAKE)
(ERROR LAMP MODE)
(STANDARD)
IN-TEMP
25.0
(48.0 ˚C)
LAMP-TEMP
44.0
(78.0 ˚C)
FAN MODE
0