The instrument was turned off while installing.
Pulling off the USB fl ash memory while installing.
Please retry to install.
No information on LCD with booting install mode.
The Flash ROM may be broken.
Replace the DM circuit board as the boot is defective.
(Operation is not available unless the MAC address is written. Be sure to replace the DM circuit board.)
Use special care in handling as turning off the power immediately after starting installation may cause damage to the
boot.
To avoid this, please don't turn the instrument off while installing.
Can't execute installation using the USB fl ash memory which was copied by the PC.
The USB fl ash memory may be damaged. Use another USB fl ash memory and try installation again.
An error message is displayed on LCD.
Please refer to the following table.
Trouble Shootings
●
error message
Install data read error!
Install data
address error!
Install data
size error!
Install data
check sum error!
Flash erase error!
Flash write error!
Flash verify error!
Flash
check sum error!
Flash ID error!
Install data does not exist!
note
to do
Cannot load the installation data from
the USB flash memory.
Please check the USB flash memory if it
will have been inserted exactly.
Please check the USB flash memory if it
will stick the dust to the face of metal.
Cannot recognize the USB flash memory,
or not exist the installation data into the
USB flash memory.
Please check the USB flash memory if it
will have been inserted exactly.
Please check the data into the USB flash
memory using the PC.
Install error!
E001
Fail to install the data.
The boot data may be incorrect.
E002
The data size is too large.
E004
An error occured during to erase data.
E003
Check sum error (Reading from the
USB flash memory) .
Please check the data correctly into the
USB flash memory.
Please retry to install the data.
Please try to use the another USB flash
memory.
E005
Cannot write data to the Flash ROM at the
assigned address.
E006
An error occured during to write data to
the Flash ROM.
E007
An error occured during to verify data into
the Flash ROM.
E008
Check sum error (Writing to the Flash
ROM) .
Содержание Clavinova CVP-405
Страница 49: ...CVP 405 CVP 405PE CVP 405PM 49 DM Circuit Board Scale 85 100 Pattern side パターン側 2NA WH51110 3 ...
Страница 59: ...CVP 405 CVP 405PE CVP 405PM 59 MA80S Circuit Board Pattern side パターン側 2NA WB55420 2 ...
Страница 63: ...CVP 405 CVP 405PE CVP 405PM 63 F F F F GH3 EBUS L Circuit Board 2NAK8 V890460 1 Pattern side パターン側 ...
Страница 65: ...CVP 405 CVP 405PE CVP 405PM 65 H H H H GH3 EBUS M Circuit Board 2NAK8 V890470 1 Pattern side パターン側 ...
Страница 67: ...CVP 405 CVP 405PE CVP 405PM 67 J J J J GH3 EBUS H Circuit Board 2NAK8 V890480 2 Pattern side パターン側 ...