ACD1 Reference Manual
7
Panel operations
By pressing buttons on the panel you can monitor or control various parameters of the ACD1 itself or of the con-
nected amplifiers.
The following parameters can be monitored/controlled.
Category
Sub category
Operation performed
1. Scene
Recall
Recalls a scene on the specified amplifier.
Store
Saves a scene for the specified amplifier.
2. Amp Control
On/Standby
Switches the power of the specified amplifier between On and Standby.
Mute
Mutes or unmutes the channel of the specified amplifier.
Attenuation
Adjusts the channel attenuator value of the specified amplifier. (PC-N/Tn series
only)
3. Output Monitor
Displays the output level of the specified amplifier.
4. Device Setup
Device ID
Specifies the ACD1’s Device ID address.
Device Label
Displays the name of the ACD1 assigned by Amp Editor.
Identify
Blinks the “Identify” icon of the corresponding ACD1 in Amp Editor.
5. Utility
Battery
Displays the state of the ACD1’s internal backup battery.
Firmware Ver.
Displays the ACD1’s firmware version.
LCD Backlight
Selects whether the ACD1’s LCD backlight will be always lit (ON) or lit only during
operation (Auto OFF).
Panel Operation
Restricts panel operations of the ACD1.
Scene Recall
Specifies whether scene recall from the ACD1’s panel is enabled (Enable) or dis-
abled (Disable).
EMG Scene Setup
Specifies the scene number that will be recalled when the EMG (Emergency) sig-
nal is received from an external controller. If this is OFF, a scene will not be
recalled even if an EMG signal is received.
Last Mem. Resume
Specifies whether the ACD1 will start up with the settings that were in effect when
the power was last turned off (ON) or whether it will start up by recalling the amp’s
scene number that was in effect when the power was last turned off (OFF).
Clock
Sets the date and time of the ACD1’s internal clock.
GPI Calibration
Calibrates the [GPI IN] connector input voltage.
6. Network Setup
IP Address Mode
Selects whether the ACD1’s IP address will be set automatically from Amp Editor
(Auto) or set manually (Manual).
IP Address
Specifies the ACD1’s IP address.
MAC Address
Displays the ACD1’s MAC address.
IP Ctrl Port #
Specifies the port number used when controlling the ACD1 via Ethernet from an
external controller such as AMX/Crestron.