CANNING
From the VFO mode, press and hold in the
B
key for one second, and
while still
holding in
the
B
key, rotate the
DIAL
knob to select
the bandwidth for the VFO scanner. Release the
B
key
to begin scanning toward a higher frequency. The scanner
will stop when it receives a signal strong enough to break
through the Squelch threshold. The
VX-8GR/GE
will then
hold on that frequency according to the setting of the “
RE-
SUME
” mode (Menu Item
77: SCAN RESUME
).
If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), just rotate the
DIAL
knob one click in the counter-clockwise direction
while the
VX-8GR/GE
is scanning. The scanning direction will be reversed. To revert to
scanning toward a higher frequency once more, rotate the
DIAL
knob one click clock-
wise.
Press the
PTT
switch briefly to cancel the scanning. See page 54 for more details regard-
ing Scan Operation.
O
PERATION
F
REQUENCY
N
AVIGATION
Dual Receive Notice
The
VX-8GR/GE
may receive very strong signals on the Image frequency, and/or
the receiver sensitivity may be somewhat reduced by the combination of the “A-
Band” and “B-Band” frequencies while Dual Receive operation is engaged.
If you experience interference that you suspect may be coming in via an “Image”
path, you may calculate the possible frequencies using the formulas below. This
information may be used in the design of effective countermeasures such as traps,
etc.
16.369 MHz x
n
11.7 MHz x
n
9.8304 MHz x
n
6.144 MHz x
n
4.9152 MHz x
n
(
n
is an integer: 1, 2, 3, …)
“A-Band” Freq. = (“B-Band” Freq. ± 46.35 MHz) x
n
“B-Band” Freq. = (“A-Band” Freq. ± 47.25 MHz) x
n
(@ “A-Band” = NFM)