FTM-350AR/AE O
PERATING
M
ANUAL
40
SYSTEM G
ROUP
G01: APO
Function
: Sets the Automatic Power-Off time.
Available Values
: OFF, 0.5 hour, 1.0 hour, 1.5 hour, 2.0 hour ~ 12.0 hour (1.0 hour/step)
Default
: OFF
G02: ARS
Function
: Enables/Disables the Automatic Repeater Shift function.
Available Values
: ON or OFF
Default
: ON
G03: AUTO STEP
Function
: Selects the DIAL frequency step.
Available Values
: AUTO, 5.00 kHz, 6.25 kHz, 8.33 kHz, 9.00 kHz, 10.00 kHz, 12.50 kHz,
15.00 kHz, 20.00 kHz, 25.00 kHz, 50.00 kHz, 100.00 kHz, or 200.00 kHz
Default
: AUTO
G04: BEEP
Function
: Adjusts the beep volume level.
Available Values
: OFF, LOW, or HIGH
Default
: LOW
G05: F KEY
Function
: Selects the function of the front panel “
F-2
” key that is located at the right-side
end of the “
F-2
” category [
SMART FUNCTION
] keys.
Available Values
: MHz, AF DUAL 1 (LINE-IN), AF DUAL 2 (AM),
AF DUAL 3 (FM), PA, SQL OFF, T-CALL, or WiRES
Default
: AF DUAL 3 (FM)
MHz:
Enables tuning of the operating frequency in 1 MHz steps using
the
DIAL
knob.
AF DUAL 1 (LINE-IN): Activates the AF Dual function while listening to the Line-In audio.
AF DUAL 2 (AM):
Activates the AF Dual function while receiving an AM broadcast
station.
AF DUAL 3 (FM):
Activates the AF Dual function while receiving an FM broadcast
station.
PA:
Activates the PA (Public Address) function which sends your voice
audio (microphone input) to the transceiver’s speaker.
SQL OFF:
Disables the SQL temporarily.
T-CALL:
Activates a 1750 Hz burst tone, used for repeater access in many
countries (especially in Europe).
WiRES:
Recalls the WiRES
TM
memory.
M
ISCELLANEOUS
S
ETTING
(
S
ET
M
ODE
O
PERATION
)
Содержание FTM-350AR
Страница 29: ...FTM 350AR AE OPERATING MANUAL 27 NOTE...