Page 134
FT
DX
9000D O
PERATION
M
ANUAL
M
ENU
M
ODE
GENERAL G
ROUP
028. ANT SELECT
Function
: Sets the method of antenna selection.
Available Values
: BAND/STACK
Default Setting
: BAND
BAND: The antenna is selected in accordance with
the operating band.
STACK: The antenna is selected in accordance with
the band stack (different antennas may be
utilized on the same band, if so selected in
the band stack).
029. BEEP LEVEL
Function
: Sets the beep level.
Available Values
: 0 ~ 255
Default Setting
: 50
030. CAT RATE
Function
: Sets the transceiver’s computer-interface
circuitry for the CAT baud rate to be used.
Available Values
: 4800/9600/38400 bps
Default Setting
: 4800 bps
031. MEM GROUP
Function
: Enables/Disables Memory Group Opera-
tion.
Available Values
: DISABLE/ENABLE
Default Setting
: DISABLE
032. QUICK SPLIT FREQ
Function
: Selects the tuning offset for the Quick Split
feature.
Available Values
: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting
: +5 kHz
033. TIME OUT TIMER
Function
: Sets the Time-Out Timer countdown time.
Available Values
: OFF/5/10/15/20/25/30 min
Default Setting
: OFF
The Time-Out Timer shuts off the transmitter after
continuous transmission of the programmed time.
034. TRV OFFSET
Function
: Set the 10’s and 1’s of the MHz digits dis-
play for operation with a transverter.
Available Values
: 30 ~ 49 MHz
Default Setting
: 44 MHz
If you connect a 430 MHz transverter to the radio, set
this menu to “30” (the “100 MHz” digits are hidden on
this radio).
035. µTUNE DIAL STEP
Function
: Select the µ-TUNE mode.
Available Values
: DIAL STEP-1/DIAL STEP-2/OFF
Default Setting
: DIAL STEP-1
DIAL STEP-1: Activates the µ-TUNE system in the
Auto mode using “
FINE
” steps of the
µ-TUNE
knob (1 step/click) on the 14
MHz and lower amateur bands on the
main band (VFO-A).
DIAL STEP-2: Activates the µ-TUNE system in the
Auto mode using “
COARSE
” steps of
the
µ-TUNE
knob (2 steps/click) on
the 7 MHz and lower amateur bands.
On the 10/14 MHz bands, “FINE” µ-
TUNE knob steps will be used (1 step/
click).
OFF:
Disables the µ-TUNE system. Acti-
vates the VRF feature on the 14 MHz
and lower amateur bands on the main
band (VFO-A).
036. MIC SCAN
Function
: Enables/disables scanning access via the
microphone’s [
UP
]/[
DWN
] keys (only available at the
rear panel’s
MIC
Jack).
Available Values
: ENABLE/DISABLE
Default Setting
: ENABLE
037. MIC SCAN RESUME
Function
: Selects the Scan Resume mode.
Available Values: PAUSE/TIME
Default Setting
: TIME
PAUSE: The scanner will hold until the signal disap-
pears, then will resume after one second.
TIME:
The scanner will hold for five seconds, then
resume whether or not the other station is
still transmitting.
038. AF/RF DIAL SWAP
Function
: Reverses the functions of the
AF GAIN
(VFO-B) and
RF GAIN
(VFO-A) knobs.
Available Values
: NORMAL/SWAP
Default Setting
: NORMAL
When this menu is set to “SWAP,” you may adjust
the sub (VFO-B) receiver audio using the large
RF
GAIN
(VFO-A) knob and adjust the main (VFO-A)
receiver RF gain using the small
AF GAIN
(VFO-B)
knob. This puts both “Volume” controls on the same
shaft.
Содержание FT DX 9000D - COMPUTER AIDED TRANSCEIVER
Страница 1: ...FTDX9000D Operation Manual...
Страница 2: ......
Страница 95: ...Page 93 FT DX 9000D OPERATION MANUAL NOTE...
Страница 101: ...Page 99 FT DX 9000D OPERATION MANUAL NOTE...
Страница 127: ...Page 125 FT DX 9000D OPERATION MANUAL NOTE...
Страница 149: ...Page 147 FTDX9000D OPERATION MANUAL NOTE...
Страница 152: ...Page 150 FTDX9000D OPERATION MANUAL NOTE...
Страница 153: ...Page 151 FTDX9000D OPERATION MANUAL NOTE...
Страница 154: ...Page 152 FTDX9000D OPERATION MANUAL NOTE...